Laserfiche WebLink
<br />SCREEN, VINYL & GLASS ROOMS <br /> <br />_F.1nfia...... Allowable Upright Heights Screen, Vinyl and Glass Room. <br />Aluminum Alloy 6063 T-6 <br /> <br />i, <br /> <br /> 2" x 2" x 0.055" Hollow Extrusion <br /> Wind Zone <br />Load 102 N,P.H, I 110 M.P.H. I 120 M,P.H. I 125 M.P.H. I 140 M.P.H. <br />Width Applied Load <br /> 19 # 'Sa. Ft. 23 # 'Sa. Ft. 26 # 'Sa, Ft. 29 # 'Sa. Ft. 36 # /Sa. Ft. <br />36" 12'-3" 11'-1" 10'-5" 9'-11" 8'-11 <br />42" 11'-4" 10'-3" 9'-8" 9'-2". 8'-3" <br />48" 10'-7" 9'-7" 9'-1" 8'-7" 7'-8" <br />54" 9'-11" 9'-1" 8'-6" 8'-1" 7'-3" <br />60" 9'-6" 8'-7" 8'-1" 7'-8" 6'-11" <br />66" 9'-0" 8'-2" 7'-9" 7'-4" 6'-7" <br />72" 8'-8" 7'-10" 7'-5" 6'-11" 6'-3" <br />78" 8'-4" 7'-7" 7'-1" 6'-9" 6'-0" <br />84" 7'-11" 7'-3" 6'-10" 6'-6" 5'-10" <br />90" 7'-9" 7'-0" 6'-7" 6'.3" 5'-7" <br /> 2" x 3" x O.OSO" Hollow Extrusion <br /> Wind Zone <br />Load 102 M,P.H. I 110 M.P.H. I 120 M.P.H. I 125 M.P.H. I 140 M,P.H. <br />Width Applied Load <br /> 19 # 'Sq. Ft. 23 # 'Sa. Ft. 26 # 'Sa. Ft. 29 # 'Sa. Ft. 36 # 'Sa. Ft. <br />36" 16'-10" 15'-3" 14'-4" 13'-7" 12'-3" <br />42" 15'-7" 14'-2" 13'-4" 12'-7" 11 '-4" <br />48" 14'-7" 13'-3" 12'-5" 11'-9" 10'-7" <br />54" 13'-9" 12'-6" 11'-9" 11'-1" 9'-11" <br />60" 13'-0" 11'-10" 11'-2" 10'-6" 9'-6" <br />66" 12'-5" 11'-3" 10'-7" 10'-1" 9'-0" <br />72" 11'-11" 10'-10" 10'-2" 9'-7" 8'-8" <br />78" 11'-5" 10'-5" 9'-9" 9'-3" 8'-4" <br />84" 11'-0" 10'-0" 9'-5" 8'-11" 8'-0" <br />90" 10'-8" 9'-8" 9'-1" 8'-7" 7'-9" <br /> <br />Load <br />Width <br /> <br /> <br />102 M.P.H. <br /> <br />36" <br />42" <br />48" <br />54" <br />60" <br />66" <br />72" <br />78" <br />84" <br />90" <br /> <br />19 # 'S . Ft. <br />20'-9" <br />19'-3" <br />17',11" <br />16'-11" <br />16'-1" <br />15'-4" <br />14'-8" <br />14'-1" <br />13'-7" <br />13'-2" <br /> <br />Notes: <br />Glass Rooms: The addition of aluminum frame windows with glass panes that are designed <br />to 110 M,P,H, wind load requirements to the above upright sizes increases the strength so that <br />additional framing is not required, <br />Using screen panel width 'W' (See typical glass room drawing,), select upright required from <br />the maximum height allowed for each extrusion, <br />Screen Splines on 3" side, extrusion turned with 3" side parallel to sole plate, <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL TANT <br />P,O. BOX 4368, SOUTH DAYTONA, FL 32121 <br />TELEPHONE (904) 767-4n4 <br />FAX (904) 767-6556 <br /> <br />@ COPYRIGHT 1999 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E, BENNETT, P,E. <br /> <br />SECTION 3 <br /> <br />SEAL <br />PAGE <br /> <br />93 <br />