<br />"-t> 1 (~
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />
<br />FORM 600B-97 Residential Component Prescriptive Method B CENTRAL 4 5 6
<br />
<br />Department of Community Affairs
<br />
<br />Compliance with Method 8 Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the use of Form 6008-97 for single and mulmamily residences of 3 stories or less in height, and
<br />additions to existing residential buildings, To comply, a building must meet or exceed all of the energy efficiency prescriptives in any ~ of the prescriptive component packages lI!ll! comply with the
<br />prescriptive measures listed in Table 68-1 of this form. An alternative method is provided for addnions of 600 square feet or less by use of Form 600C-97. If a building does not comply wnh this method,
<br />it ma still com I under other sec1ions in Cha ter 6 of the Code.
<br />
<br />
<br />OWNER: ~ev;VI
<br />
<br />GENERAL DIRECTIONS
<br />1, New construction including additions which incorporates any of the following features cannot comply using this method: steel stud walls, single assembly roof/ceiling
<br />construction, or skylights or other non-vertical roof glass.
<br />2. Choose one of the component packages "A" through "F" from Table 6B-1 by which you intend to comply with the Code, Circle the column of the package you have chosen.
<br />3. Fill in all the applicable spaces of the "To Be Installed" column On Table 6B-1 with the informatiOn requested. All "To Be Installed" values must be equal to or more efficient
<br />than the required levels.
<br />4, Complete page 1 based on the "To Be Installed" column information,
<br />5, Read "Minimum Requirements for All Packages", Table 6B-2 and check each box to indicate your intent to comply with all applicable items.
<br />6. Read, sign and date the "Prepared By" certification statement at the bottom of page 1, The owner or owner's agent must also sign and date the form.
<br />
<br />Please Print
<br />
<br />1. Compliance package chosen (A-F)
<br />2. New construction or addition
<br />3. Single family detached or Multifamily attached
<br />4. If Multifamily-No. of units covered by this submission
<br />5. Is this a worst case? (yes I no)
<br />6. Conditioned floor area (sq. ft.)
<br />7. Predominant eave overhang (ft.)
<br />8. Glass type and area:
<br />a. Clear glass
<br />b. Tint, film or solar screen
<br />9. Percentage of glass to floor area
<br />10. Floor type, area or perimeter, and insulation:
<br />a. Slab on grade (R-value)
<br />b. Wood, raised (R-value)
<br />c. Wood, common (R-value)
<br />d. Concrete, raised (R-value)
<br />e. Concrete, common (R-value)
<br />11. Wall type, area and insulation:
<br />a. Exterior: 1. Masonry (Insulation R-value)
<br />2. Wood frame (Insulation R-value)
<br />b. Adjacent: 1. Masonry (Insulation R-value)
<br />2. Wood frame (Insulation R-value)
<br />12. Ceiling type, area and insulation:
<br />a. Under attic (Insulation R-value)
<br />b. Single assembly (Insulation R-value)
<br />13. Air Distribution System: Duct insulation, location
<br />14. Cooling system
<br />(Types: central, room unit, package terminal A,C., gas, none)
<br />
<br />15. Heating system:
<br />(Types: heat pump, elec. strip, nat. gas, L.P, gas, gas h.p., room or PTAC, none)
<br />
<br />16. Hot water system:
<br />(Types: elec., nat. gas, L.P. gas, solar, heat rec., ded. heat pump, other, none)
<br />
<br />I hereby certify that the plans and ~edificalions covered by the calculation are in compliance with the
<br />Florida Energy Code, . ~ ~ ~ . ) . ~'
<br />
<br />PREPARED BY: <, DATE: '13'"-.., t. 7/
<br />I hereby certify that is it~e Florida Energy Code,
<br />
<br />OWNER AGENT: DATE: ~,~ [.l)'C;
<br />
<br />-1-
<br />
<br />c..t'.: /,
<br />CLlMAT
<br />ONE: 4~5D6D
<br />JURISDICTION NO.: ~
<br />
<br />CK
<br />
<br />12a.
<br />12b.
<br />13.
<br />14a.
<br />14b.
<br />14c.
<br />15a.
<br />15b.
<br />15c.
<br />16a.
<br />16b.
<br />
<br />R= ~~ 0 i ~ j 0 sq. ft.
<br />R= sq. ft.
<br />R= b u .u c ~ /
<br />Type: (.'c;;JK( It <l (
<br />SEERlEER: /0, v c..
<br />Capacity: ~.." JC, 0
<br />Type: .~,~
<br />HSPF/COP/AFUE:
<br />Capacity: 3 & t9 C/ ;)
<br />Type: 1.. (t"({
<br />EF: i C; (
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance
<br />with the Florida Energy Code. Before construction is completed, this building will be
<br />inspected for compliance in a ance with ction 553.908, F.S.
<br />
<br />
<br />DATE:
<br />
<br />Revised 1998
<br />
|