Laserfiche WebLink
<br />SIDE NOTCH POST TO BEAM CONNECTION <br /> <br />'----- ANCHOR PER DETAIL FOR PAN OR <br />COMPOSITE PANEL <br />SEE TABLE 2,3 FOR NUMBER OF <br />60L TS AND SIZE OF POST <br /> <br />/; <br /> <br />BEAM SPAN <br />....V" FOR BEAM SIZE <br /> <br />SEE TABLE 2 , 1 , , ANDIORT ABLE 2. , ,2 <br />AFTER COMPVT1NG "A' LARGEST VALUE <br /> <br />/~ <br />r <br /> <br />~ rl <br />I I _ _ I <br />(2)#'Ox'"SHEETMETALSCREYV ~l.r - <br />INTO SCREW SLOTS <br />ANCHOR 1" x 2" PLATE TO CONCRETE I <br />WITH 114" X 2-1/2" CONCRETE L~ <br />ANCHORS W1THIN 6' OF EACH SIDE <br />OF EACH POST AND 24" O,C, MAX. ,--'1 <br /> <br />I~ <br /> <br />'" X 7: EXTRUSION <br /> <br />BEAMMEADER <br />Al TERNA TE CONNECTION DETAIL <br />7: x 7: X 0,063" ANGlE CONNECT <br />UPRIGHT @ BEAMIHEADER AND <br />CKAJR RAIL <br /> <br />POST SIZE PER <br />TABLE 2,2,1 AND/OR <br />TABLE 2,2,2 <br /> <br /><Il <br />UJ <br />~ <br /> <br />ROOF PANEL SEE SECTION 7 <br /> <br />SIDE VI'2N SINGLE OR DOUBLE BAY CARPORT <br /> <br />i'J'iEE BRACE NOT REQUIRED FOR <br />ATTACHED STRUCTURES <br />i'J'iEE BRACE REQUIRED IF POST NOT <br />SET IN CONCRETE FOOTING <br /> <br />PAN OR COMPOSITE PANEL ROOF <br /> <br /> <br />,.'/8" MIN. IN CONCRETE <br /> <br /> <br />MIN, 3-,12" SlAB 2500 PSI CONC, <br />ExS-10x'0 W'w,M. OR FIBER MESH <br /> <br />VAPOR BARRIER UNDER CONCRETE <br /> <br /> <br />I <br />CENTER OF /1 <br />BRACE CONNECTION FOR <br />START OR END OF BEAM SPAN <br />]I'- KNEE B E <br />LENGTl-I <br />H-GKANNEL K."IEE BRACE 7: X 3" X O,OSO" KNEE <br />BRACE WITH (3) *'0 X 112" EACH SIDE OF BEAM <br />U-<:KANNEL ON SIDE W1TH (3) #10 X 1/2" AND 1 <br />'<NEE BRACE :STO POST ,\NO (3) #10:: ~:7: EACH I A, <br />. .S;C~ nF ~'3AACE Wm1~RROs;uN ~ I <br />RESISTM W/o.SHER HEADED SCREWS <br />BEAM PERPENDICULAR TO ROOF BEAM PARAlLEL TO ROOF <br />KNEE BRACE TO POST DETAIL <br /> <br />HOLLOW POST TO BASE AND HOLLOW POST TO BEAM DETAIL <br /> <br />~: ~.~ <br />(4) #'0 X 112" S.M.S. EACH SIDE <br />OF POST <br /> <br />7: X 7: OR 7: X 3" OR 7: 5MB POST ______ , <br /> <br />t-I:;~ -1 <br />. I I <br />t+io ------ <br />ANCHOR 1" X 2" PlATE TO CONCRETE I', <br />IVlTl-l '/4" X 2.1/2" CONCRETE ..!...../'_ <br />ANCHORS W1THIN S" OF EACH SIDE '/ <br />uF EACH POST AT 24" O,C, MAX. <br />OR Tl-IROUGH ANGLE AT 24" O,C, MAX. ~V1 <br /> <br /> <br />, --=-.Jr ~ r:- <br />~~ <br />MIN. 3-,12" SlAB 2500 PSI CONC. 'ffi' '." . J. <br />6x6-'Ox'0 W'w,M, OR FIBER MESH " <br />VAPOR BARRIER UNDER CONCRETE <br /> <br /> <br />H-8AR OR. GUSSET PlATE <br />7: X 7: X 1116" ANGLE EACH SIDE <br />ATTACH TO POST AND CONCRETE <br />AT LOAD B.:ARING WALL W1TH <br />(2) #'0 x 112" S.M.S, EACH SIDE <br />'" X 7: EXTRUSION <br /> <br /><Il <br />UJ <br />~ <br />! <br /> <br />ROOF PANEL SEE SECTION 7 <br /> <br />HEADER BEAM <br /> <br />PLATE TO BE SAME Tl-iICKNESS <br />AS BEA.'-o\ WEa <br />PlATE CAN BE INSIDE OR <br />OUTSIDE BEA.'-o\ OR. LAP CUT <br />i'- d- SO" + d-.5O" --I" '" MAX. <br />, "1--,< <br />SELECT FASTENERS FROM l75' ~I - - - - - " - - I ~< I <br />TABLE1.e ~ : "1 ~ '0 <br />I 75" >,--L - - - - - - - - ~ I <br />" ", :~ <br />DENOTES SCRE'"," PATTERN '"!.'AX.. <br />NOT NUMBER OF SCREWS <br /> <br />SPLICE TO BE LOCATED '14 TO 1/3 <br />BEAM SPAN AND STAGGERED EACH <br />SIDE OF SELF MATING BEAM <br /> <br />'.1/8" MIN. IN CONCR-qe <br /> <br />d = HEIGHT OF BEAM <br />BEAM SPLICE SHALL BE MINIMUM <br />d - ,SO" HEIGHT <br />2 X (d - ,SO') LENGTH <br /> <br />l...A <br /> <br />SELECT FASTENER SIZE. NUMBER <br />AND SPACING FROM TABLE' ,6 <br /> <br />SELF-MATING POST TO BASE AND SELF-MATING POST TO <br />BEAM DETAiL <br /> <br />CENTER NOTCH POST TO BEAM CONNECTION <br /> <br />IYPICAL BEAM SPLICE DETAIL <br /> <br />ANGLE OR RECENlNG CKANNEL <br /> <br />'.112" x '.'12" x 0080' ANGLE <br />EACH SIDE Of CONNECTING <br />BEA.'-o\ WITH SCRE'WS AS SHOWN <br /> <br />~@ ~ <br />J@ ~ I <br />..! @ ~ PRIMARY BEAM <br />~ ~ SEETABLE2,1,' <br />'1 @ J: ANDIOR TABLE 2,' ,2 <br />1"@fut' <br />-@ 0 <br />II ., I <br /> <br />I MINIMUM IIa S,M.S, x :Y4' LONG NUMBER <br />, REQUIRED EQUAl TO BEAM DEPTl-IIN INCHES <br />~ NOTE: EXTRUSIONS W1TH ISTERNAL SCRE'W BOSSES <br />MAY BE CONNECTED WITH (2) #10 X '.112" <br />INTERNAlJ. Y <br /> <br />I <br /> <br />I <br />1 <br />I <br /> <br />"\~ <br />~ @ <br />~ @ <br />f- <br />PR; MA.=<.Y BEA.\l I%: @ <br />SEETABLE2,1,1 w <br />AND/OR TABLE 2 , , , 2 ~ @ <br />0: @ <br />~ @ <br /> <br /> <br />NOTE: CROSS BEAM ATTACHED AT COlUMN AND BEAM <br /> <br />CARRIER BEAM <br />SEE TABLE 2 ' , ,3 <br /> <br /> <br />MISiMUM IIa S,M.S, X :Y4" LONG <br />,NUMBER REOUIRED EOCAl TO BEAM DEPTH <br /> <br />NOTE: EXTRUSIONS W1Tl-1 iNTE.'<NAL SCREW BOSSES <br />MAY BE CONNECTED W1TH (2) #10 X '.112" <br />iNTERNAlJ. Y <br /> <br />BEA.'-o\ PER DESIGN TABLE <br /> <br />CARRIER BEAM TO BEAM CONNECTION <br /> <br />CARRIER BEAM TO WALL CONNECTION <br /> <br />CROSS BEAM AT COLUMN AND AT BEAM <br /> <br />BEAM TO WAlL CONNECTiON <br />(2) 7: X 2" x 0,060" EXTERNALLY MOUNTED ANGLES ATTACHED TO WOOO WAlL W1Tl-1 MINiMUM <br />(2) 3/8" X 2' LAG SCREYVS PER SIDE OR (2) 114" x 2."." ANCHORS TO CONCRETE OR MASONRY <br />WAlL ADD (1) ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" <br />(AlTERNATE) <br />(1) '.3.... X '-:Y4" X 1.314' X 1/8" INTERNAL U-CUP ATTACHED TO WOOD WAlL WITH MIN, (3) 3/8" X 7: <br />LAG SCREWS PER SIDE OR (3) "4" X 2.114' ANCHORS TO CONCRETE OR MASONRY WAlL ADO <br />(1) ANCHOR PER SIDE FOR EACH INCH OF CAIHllEYERED BEAM DEPTH LARGER THAN 3" <br /> <br />ANCHOR PER DETAIL FOR PAN <br />OR COMPOSITE PANEL <br />SEE TABLE 2,3 FOR NUMBER OF <br />BOlTS AND SIZE OF POST <br /> <br />BEAM A."I0 POST SlZES SEE <br />TABlE 2. , . " TABLE 2.1 .2 A....D I <br />OR TABLE 2,2, " TABLE 2,2,2 <br />COlUMN NOTCHED TO SUIT <br /> <br />BEAM AND POST SIZES SEE <br />TABLE 2. , ,1, TABLE 2.1 ,2 A....D I <br />OR TABLE 2,2.1, TABLE 2,2,2 <br />COlUMN NOTCHED TO SUIT <br /> <br />'" X 2 \18" x 00<<" CHANNEL <br />wi IIa X 318" wi HEAD S,M.S, <br />@ , '12" OC, MAX. BOTH SIDES <br /> <br />(2) IIa X 112" wi HEAD S,M.S, <br />PARAllEL @ '12" O,C, MAX. <br />THROUGH \" x 21/8" CHANNEL <br />INTO BEAM <br /> <br />(2) 51'6" X 3112" <br />CAD, ST. BOlTS THROUGH <br /> <br />...J <br />~ <br />(/):::l <br />o Z <br />W~ <br />J: ~ <br />(/)Z <br />od() <br />(/)U5:3 <br />C!W:< <br />WOf- <br />>(/)W <br />owo <br />Ua:N <br />O:::l <br />f=f-z <br />~u~ <br />n.:::lr- <br />. a: U <br />(/)f-W <br />f-(/)(/) <br />a:~ <br />o:::l <br />n. Z <br />C!_ <br />~~ <br />U:::l <br />...J <br />~ <br /> <br />~ <br />w ~_ <br />..... '" <br />a.. ::l - <br />",,'" <br />_ 2: ::: <br />~ 8 u.. ~ <br />Q)~<''''' <br />2~~~~ <br />~3~~~ <br />, ~ ;:: ;;; :i:' <br />w~g~e <br />Q)-t~S:~ <br />UllJowc.. <br />llJn.... <br />C3;;~ <br />Q) \:l 0 <br />'- <: <:l <br />~~o <br />ro~ <br /> <br />.-JZ <br /> <br /> <br />3 <br /> <br />OF <br /> <br />7 <br /> <br />~ -~'..: -'~ <br />