<br />FORM 600A-97
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE
<br />
<br />FOR BUILDING CONSTRUCTION
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br />SilverOaks Village Lot 18 Plan A 6jfCJA6t?VFBuilder: . Vari Homes .-~
<br />Lot: 18, Sub: SOV Ph I, Plat: PB 1 Page 5~ . Permitting Office: (!/,ilf tJF .-ZE?/lqL//Jusr
<br />Zephyrhills, FI Permit Number: 9~~o6 :
<br />Vari Construction Services Jurisdiction Number: C::, /16 iJU .1
<br />Central
<br />
<br />Project Name:
<br />Address:
<br />City, State:
<br />Owner:
<br />Climate Zone:
<br />
<br />1. New construction or existing
<br />2, Single family or multi-family
<br />3, Number of units, if multi-family
<br />4, Number of Bedrooms
<br />5. Is this a worst case?
<br />6. Conditioned floor area (ft2)
<br />7. Glass area & type
<br />a, Clear - single pane
<br />b. Clear - double pane
<br />c, Tint/other SC/SHGC - single pane
<br />d. Tint/other SC/SHGC - double pane
<br />8, Floor types
<br />a. Slab-On-Grade Edge Insulation
<br />b, N/A
<br />c, N/A
<br />9. Wall types
<br />a, Frame, Wood, Exterior
<br />b. Frame, Wood, Adjacent
<br />c, N/A
<br />d, N/A
<br />e. N/A
<br />10. Ceiling types
<br />a. Under Attic
<br />b. N/A
<br />c. N/A
<br />II. Ducts
<br />a, Sup: Unc. Ret: Unc. AH: Attic
<br />b, N/A
<br />
<br />New
<br />Single family
<br />1
<br />3
<br />Yes
<br />1186 ft2
<br />
<br />526,2 ft2
<br />0.0 ft2
<br />0,0 ft2
<br />0,0 ft2
<br />
<br />R=O.O, 175.2(p) ft
<br />
<br />R=11.0, 1450,0 ft2
<br />R=11.0, 287.0 ft2
<br />
<br />R=30,0, 1186.0 ft2
<br />
<br />Sup. R=6,0, 125,0 ft
<br />
<br />12, Cooling systems
<br />a, Central Unit
<br />
<br />Cap: 24.0 kBtu/hr
<br />SEER: 10.00, Unducted
<br />
<br />b. N/A
<br />
<br />c. N/A
<br />
<br />13. Heating systems
<br />a, Electric Heat Pump
<br />
<br />Cap: 24,0 kBtu/hr
<br />HSPF: 7,00, Unducted
<br />
<br />b, N/A
<br />
<br />c. N/A
<br />
<br />14, Hot water systems
<br />
<br />a. Electric Resistance
<br />
<br />Cap: 40,0 gallons
<br />EF: 0,90
<br />
<br />b. N/A
<br />
<br />c. Conservation credits
<br />(HR-Heat recovery, Solar
<br />DHP-Dedicated heat pump)
<br />15, HVAC credits
<br />(CF-Ceiling fan, CV-Cross ventilation,
<br />HF-Whole house fan,
<br />PT -Programmable Thermostat,
<br />RB-Attic radiant barrier,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />CF,
<br />
<br />[-__G_la_S_s/F_I;~;~__re~: _0_.44_ __ T. o_ta_1 as-built points: 41824.00---. PAS S
<br />_ Total base points: 54266.00
<br />
<br />-~-- ---
<br />
<br />I hereby certify that the .Plans and specifications covered!
<br />by this calculation are in compliance with the Florida
<br />Energy Code.
<br />
<br />PREPAR Francis J Vari
<br />
<br />OAT.
<br />
<br />
<br />,----- .-------..-----
<br />
<br />I Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code,
<br />Before construction is completed
<br />this building will be inspected for
<br />compliance with Section 553,908
<br />Florida Statutes,
<br />
<br />
<br />EnergyGauge@ (Version: FLRCNA-200)
<br />
|