<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: Lot: 18, Sub: SOV Ph I, Plat: PB 1 Page 55, Zephyrhills, FI, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br />Maximum:,3 cfm/saJI. window area; .5 cfm/sq.ft. door area, <br />Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends I <br />_ __ _ __ Jrom, and is sealed to, the f,Qund_atioll to the top plate. _ _ _ _ __ _ _ ___ <br />606.1.ABc.1.2.21 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />I EXCEPTION: Frame floors where a continuous infiltration barrier IS installed that is sealed I <br />1----.-- - - - _ _ _ _ _ _ . _ _I to the peril'l'l,eter, penetration~cln_d seams, _ _ __ __ __ ___ ~ <br />Ceilings 606, 1.ABC, 1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, I <br />tOffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is , <br />- _._L---____ installe.d that is sealed at the perimeter, at penetrations and seams, __ __ _ --+ <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, in,stalle d inside a, J <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />__ '--_ conditioned space, tested, __..___.__._ __ <br />Multi-storv Houses 606.1,ABC.1.2.5 Air barrier on perimeter of floor cavitv between floors, ----------0-- <br />Additional Infiltration reqts 606.1 ,ABC, 1.3 Exhaust fans vented to outd,oor,s,,' dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br />-. - -. . <br /> <br />COMPONENTS <br />Exterior Windows & Doors <br />Exterior & Adjacent Walls <br /> <br />SECTION <br />606.1 ,ABC, 1,1 <br />606.1.ABC.1.2,1 <br /> <br />CHECK <br /> <br />Floors <br /> <br />- <br /> <br />-- <br /> <br />HVAC Controls <br />-~.._-----. <br />Insulation <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br />COMPONENTS SECTION m . R~QUIREM~NTS_ _ ____ __ __ CHECK <br />Water Heaters 612, 1 l~omPIY with efficiency requirements in Table 6-12, Switch or clearly marked circuit <br />breaker (electr~~LJt()fU~Jll1lJ!lt be provided. External or built~lnJ'!.~~ap required. <br />Swimming Pools & Spas 1612.1 Spas & heated pOOls must have covers (except solar heated). Non-commercial pools <br />I must have a pump timer. Gas spa & pool heaters must have a minimum thermal I <br /> <br />S~wer hea~---- -~2-:1 1 :~~~~f1C::~u8s:O~e-restricted t~no ~~~;th~ 2~5g~l~n;~r min~t~--;t80PSIG,-----t----' <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically l' <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610, I <br />Ducts in unconditioned attics: R-6 min. insulation, , <br /> <br />:~:: ~,602.1---. ~:i1i~;~~~~:.~:~~:~~:nm;:I~:IF~::~t~~;~i~:~~~~~~;t~~he:i~::~st;rD..=- ==-f <br /> <br />Common ceiling & floors R-11. . <br /> <br />EnergyGauge ™ DCA Form 600A-97 <br /> <br />EnergyGauge@/FlaRES'97 FLRCNA-200 <br />