<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />ADDRESS: Lot: 17, Sub: SOV Ph I, Plat: PB 1 Page 55, Zephyrhills, FI,
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE n ~'H CHECK
<br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sqJt. door area. ----------
<br />Exterior & Adjacent Walls 606.1.ABC,1 ,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> I penetrations; between wall panels & top/bottom plates; between walls and floor.
<br /> , EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br />-------._, ._- from, and is sealed to, the foundation to the top plate. ~._.__._._~.__.- ---
<br />Floors Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the perimeter, penetrations and seams. ."----.-------- - --- -------- -"-'-
<br />Ceilings 606,1 ,ABC.1 ,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; ,
<br /> I
<br /> I attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> i installed that i_~ sealed at the perimeter, at penetrations and seams.
<br />1------------- ----- e---- -.------ ---------,--- -------
<br />Recessed Lighting Fixtures 606, 1.ABC, 1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br /> - conditioned space tested, - 0'_____----------- _._..__________.._~________ _
<br />Multi-storv Houses 606.1 ABC.,.2.5-1r ,,,rio'," "",;mete"ffloo, ",,;ty be!wee" ~oo""_____ _ __ __ _ _ .
<br />Additional Infiltration reqts 606.1.ABC.1.3, " Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br />_ _m. J , _ ,have combustion air. _ ___ " _ _, _ "
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences.
<br />COMPONENTS SECTION
<br />Water Heaters 612.1
<br />
<br />Swimming Pools & Spas
<br />
<br />612.1
<br />
<br />Shower heads
<br />Air Distribution Systems
<br />
<br />.2.Rt_
<br />1610,1
<br />I
<br />
<br />HVAC Controls
<br />Insulation
<br />
<br />- - -- ri: --- --
<br />607.1
<br />604,1, 602,1
<br />
<br />EnergyGaugeâ„¢ DCA Form 600A-97
<br />
<br />REQUIREMENTS lCHECK
<br />- - -- - - - --- -- - - - - -- --
<br />Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit
<br />breaker electric or cutoff as must be rovided, External or built-in heat trap required, _
<br />Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br />efficiency of 78"1<>.. _ _u_
<br />-'N.~er flQ.'iV rTlust be J!l~dcted tClI1<LrTlor.e thl!fl.. 2~Lons per r:!linute atll.Q..pSJ.<L
<br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
<br />Ducts in unconditioned attics: R-6 min. insulation.
<br />_ ___ r:separate readily accessible manual or automatic thermostat for each system,
<br />Ceilings-Min, R-19. Common walls-Frame R-11 or CBS R-3 both sides.
<br />Common ceiling & floors R-11.
<br />
<br />EnergyGauge@/FlaRES'97 FLRCNA-200