<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br />-_..,,~ - ."..~~----
<br />SilverOaks Village Lot 26 '.f/:l5 1'15II/J1'<'llF"lJR.
<br />Lot: 26, Sub: SOV Ph I, Plat: PB 1 Page 55
<br />Zephyrhills, FI
<br />Vari Construction Services
<br />Central
<br />
<br />FORM 600A-97
<br />
<br />Project Name:
<br />Address:
<br />City, State:
<br />Owner:
<br />Climate Zone:
<br />
<br />~ c~nstruction or existing
<br />2, Single family or multi-family
<br />3. Number of units, if multi-family
<br />4. Number of Bedrooms
<br />5. Is this a worst case?
<br />6, Conditioned floor area (fl:2)
<br />7. Glass area & type
<br />a. Clear - single pane
<br />b. Clear - double pane
<br />c. Tint/other SC/SHGC - single pane
<br />d. Tint/other SC/SHGC - double pane
<br />8. Floor types
<br />a, Slab-On-Grade Edge Insulation
<br />b, N/A
<br />c. N/A
<br />9. Wall types
<br />a. Frame, Wood, Exterior
<br />b. Frame, Wood, Adjacent
<br />c. N/A
<br />d. N/A
<br />e. N/A
<br />10. Ceiling types
<br />a. Under Attic
<br />b, N/A
<br />c. N/A
<br />11. Ducts
<br />a. Sup: Unc. Ret: Unc, AH: Attic
<br />b. N/A
<br />
<br />New
<br />Single family
<br />1
<br />3
<br />Yes
<br />1410 fl:2
<br />
<br />197,5 fl:2
<br />0,0 tl:2
<br />0,0 ft'
<br />0,0 ft2
<br />
<br />R=O,O, 199,0(p) ft
<br />
<br />R=I1.0, 1743.0 ft2
<br />R=I1.0, 222,0 ft2
<br />
<br />R=30.0, 1410.0 ft'
<br />
<br />Sup. R=6,0, 150,0 ft
<br />
<br />I
<br />I
<br />I..,
<br />
<br />Builder: Vari Homes i
<br />Permitting Office: (ZlT'f of :z;~Ptlt{I!III(L5 i
<br />Permit Number: '103M _
<br />Jurisdiction Number: l::'11 (.:,oc)
<br />
<br />12. Cooling systems
<br />a. Central Unit
<br />
<br />Cap: 30.0 kBtu/hr
<br />SEER: 10.00, Unducted
<br />
<br />b. N/A
<br />
<br />c, N/A
<br />
<br />13. Heating systems
<br />a. Electric Heat Pump
<br />
<br />Cap: 30,0 kBtu/hr
<br />HSPF: 7,00, Unducted
<br />
<br />b. N/A
<br />
<br />c. N/A
<br />
<br />14, Hot water systems
<br />
<br />a, Electric Resistance
<br />
<br />Cap: 40,0 gallons
<br />EF: 0,90
<br />
<br />b, N/A
<br />
<br />c. Conservation credits
<br />(HR-Heat recovery, Solar
<br />DHP-Dedicated heat pump)
<br />15. HVAC credits
<br />(CF-Ceiling fan, CV-Cross ventilation,
<br />HF-Whole house fan,
<br />PT-Programmable Thermostat,
<br />RB-Attic radiant barrier,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />CF, _
<br />
<br />Glass/Floor Area: 0.14
<br />
<br />Total as-built points: 37769.00
<br />Total base points: 58275.00
<br />
<br />PASS
<br />
<br />Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code.
<br />Before construction is completed
<br />this building will be inspected for
<br />compliance with Section 553.908 ~ :\)
<br />Florida Statutes. C'OD Wl!. ~
<br />
<br />
<br />-E~e~YGauge@ (V~ffi~~f~~~--- -.
<br />
<br />I hereby certify that the plans and specifications covered
<br />by this calculation are in compliance with the Florida
<br />Energy Code.
<br />
<br />PREPARED BY: Francis J Vari
<br />DATE: ~15i?y
<br />I C
<br />I hereby certify that this building, as designed, is in
<br />compliance with the Flori Co
<br />OWNERlA
<br />DATE:
<br />
<br />
<br />
|