Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: Lot: 26, Sub: SOV Ph I, Plat: PB 1 Page 55, Zephyrhil/s, FI, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br />COMPONENTS SECTION REQUIREMENTS __ _________ ___________ _ <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />_breaker (ele~tric) or cutoff (gas) must~ovid~.d.~~~rnaLor built-in heat trap required, <br />I Spas & heated pools must have covers (except solar heated), Non-commercial pools <br />.~~ust have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />_ efficiency of 7_8%,__ __ _ _ _ _____ ___ <br />_ _Water flOW mJ,lst b~ restricted to no mor~ than 2.5 gallons per minute at 80 PSIG,__ <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br />+.9ucts in unconditioned attics: R-6 min. insulation. <br />___L~epara~.J!ladily accessible manual or automaticthermostat for each system, ,_ <br />I Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11, <br /> <br />COMPONENTS <br /> <br />Exterior Windows & Doors <br />Exterior & Adjacent Walls <br /> <br />SECTION <br />606,1.ABC.1.1 <br />606.1.ABC,1,2.1 <br /> <br />I <br />---,-, -------1------- <br /> <br /> <br />:::, .. - -I :;: ::: ::: <br />1 <br /> <br />Recessed Lighting Fixtures <br /> <br />606.1.ABC.1.2A <br /> <br />r------------- ------ <br />Multi-story Houses <br />Additional Infiltration reqts <br /> <br />606,1 ,ABC, 1.2.5 <br />606, 1.ABC, 1.3 <br /> <br />Swimming Pools & Spas <br /> <br />612.1 <br /> <br />I <br />_ ~]~11J <br />1610.1 <br /> <br /> <br />------ -----------, "--'---f:" _ ----: -~ -,-,- <br />HVAC Controls 607,1 <br />Insulation 604,1, 602,1 <br />I <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />EnergyGauge ™ DCA Form 600A-97 <br /> <br />PERMIT #: <br /> <br />REQUIREMENTS FOR EACH PRACTICE CHECK <br />Maximum:.3 cfm/saJt window area; .5 cfm/saJt door area, <br />Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; , <br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility "l <br />penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from and is sealed to, the foundation to the top plate,______ ___ _______ __ <br />Penetrations/openings >1/8" sealed unless backed by truss or joint members. I <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the perimeter, penetrations and seams. ___ __ ------------------t--- <br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />jI1,g~lIed thati~ se~l~cljlUhe perirTleterLa.!..Q~netrCl!ions._al1cl seall1l>'. i- <br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a I <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from ' <br /> <br />E~:::~;~:~::::::;::=~:~o:~::.te~ ~mPIY W'~NFPA+ . <br /> <br />have combustion air. i <br /> <br />CHECK <br /> <br />EnergyGauge@/FlaRES'97 FLRCNA-200 <br />