<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />ADDRESS: Lot: 26, Sub: SOV Ph I, Plat: PB 1 Page 55, Zephyrhil/s, FI,
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences.
<br />COMPONENTS SECTION REQUIREMENTS __ _________ ___________ _
<br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
<br />_breaker (ele~tric) or cutoff (gas) must~ovid~.d.~~~rnaLor built-in heat trap required,
<br />I Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br />.~~ust have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br />_ efficiency of 7_8%,__ __ _ _ _ _____ ___
<br />_ _Water flOW mJ,lst b~ restricted to no mor~ than 2.5 gallons per minute at 80 PSIG,__
<br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610,
<br />+.9ucts in unconditioned attics: R-6 min. insulation.
<br />___L~epara~.J!ladily accessible manual or automaticthermostat for each system, ,_
<br />I Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides.
<br />Common ceiling & floors R-11,
<br />
<br />COMPONENTS
<br />
<br />Exterior Windows & Doors
<br />Exterior & Adjacent Walls
<br />
<br />SECTION
<br />606,1.ABC.1.1
<br />606.1.ABC,1,2.1
<br />
<br />I
<br />---,-, -------1-------
<br />
<br />
<br />:::, .. - -I :;: ::: :::
<br />1
<br />
<br />Recessed Lighting Fixtures
<br />
<br />606.1.ABC.1.2A
<br />
<br />r------------- ------
<br />Multi-story Houses
<br />Additional Infiltration reqts
<br />
<br />606,1 ,ABC, 1.2.5
<br />606, 1.ABC, 1.3
<br />
<br />Swimming Pools & Spas
<br />
<br />612.1
<br />
<br />I
<br />_ ~]~11J
<br />1610.1
<br />
<br />
<br />------ -----------, "--'---f:" _ ----: -~ -,-,-
<br />HVAC Controls 607,1
<br />Insulation 604,1, 602,1
<br />I
<br />
<br />Shower heads
<br />Air Distribution Systems
<br />
<br />EnergyGauge ™ DCA Form 600A-97
<br />
<br />PERMIT #:
<br />
<br />REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Maximum:.3 cfm/saJt window area; .5 cfm/saJt door area,
<br />Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; ,
<br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility "l
<br />penetrations; between wall panels & top/bottom plates; between walls and floor.
<br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br />from and is sealed to, the foundation to the top plate,______ ___ _______ __
<br />Penetrations/openings >1/8" sealed unless backed by truss or joint members. I
<br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br />to the perimeter, penetrations and seams. ___ __ ------------------t---
<br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br />attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br />jI1,g~lIed thati~ se~l~cljlUhe perirTleterLa.!..Q~netrCl!ions._al1cl seall1l>'. i-
<br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a I
<br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from '
<br />
<br />E~:::~;~:~::::::;::=~:~o:~::.te~ ~mPIY W'~NFPA+ .
<br />
<br />have combustion air. i