Laserfiche WebLink
<br />. SECTION 2 <br /> <br />ATTACHED & FREESTANDING COVERS AND UTILITY SHEDS <br /> <br /> <br />A' <br /> <br /> <br />INTERNAL OR EXTERNAL RECEIVING CHANNEL <br />SCALE: 1/4" = 1" <br /> <br /> <br />2" x 2" x 0.063" ANGLES <br /> <br />A <br /> <br /> <br />INTERNAL OR EXTERNAL ANGLE CLIPS <br />SCALE: 1/4" = 1" <br /> <br />ALUMINUM TUBE COLUMN <br /> <br />CONCRETE ANCHORS (SEE <br />SCHEDULE) <br /> <br />~ <br /> <br />EXTRUDED ALUMINUM BASE <br />OR BREAK FORMED U-CLlP <br /> <br />~( <br /> <br /> <br />q <br /> <br />CORROSION RESISTIVE STEEL <br />THRU BOLT PER SCHEDULE <br /> <br />A <br /> <br /> <br />CONCRETE SLAB OR FOOTING <br /> <br />NOTE: ATTACHMENT DETAILS SHOWN REQUIRE <br />DIAGONAL BRACING FOR FREE-STANDING <br />COVERS <br /> <br />TUBE COLUMN BASE SCHEMATIC INTERNAL BASE <br />SCALE: 1/4" = 1" <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL TANT <br />P.O. BOX 4368. SOUTH DAYTONA. FL 32121 <br />TELEPHONE (904) 767.4774 <br />FAX (904) 767-6556 <br /> <br />SEAL <br /> <br />PAGE <br /> <br />@ COPYRIGHT 1999 <br />60 NOT TO BE REPROOUCED IN WHOLE Ok IN PART WITHOUT THE WklTIEN PERMISSION Of LAv'JklNL.! I IlLNM I I 1'1 <br />