Laserfiche WebLink
<br />SCREEN, VINYL & GLASS ROOMS <br /> <br />.F.1il~IlIiJlli" Allowable Beam Spans 0 Hollow Extrusions for Screen <br />and I or Vinyl [Open] Rooms with Solid Roofs <br /> <br />Aluminum Alloy 6063 To6 <br /> Wind Zone <br /> 102 MPH I 110 MPH I 120 MPH I 125 MPH I 140 MPH <br /> Applied Load <br /> 17#/ Sa. Ft. I 20 # / Sa. Ft. I 23 # / Sa. Ft. I 26 # / Sa. Ft. 32 # / Sa. Ft. <br />Load Width 2" x 2" x 0.032" <br />5' 6'-3" 5'-9" 5'-4" 5'.0" 4'.6" <br />6' 5'.8" 5'.3" 4'.11" 4'.7" 4'.2" <br />7' 5'.3" 4'-10" 4'.6" 4'.3" 3'.10" <br />8' 4'.11" 4',.6" 4'.3" 3'.11" 3'.7" <br />9' 4'.8" 4'.3" 3'.11" 3'.9" 3'.5" <br />10' 4'.5" 4'.1" 3'.9" 3'.7" 3'.3" <br />11' 4'.2" 3'.10" 3'.7" 3'.5" 3'.1" <br />12' 4'.0" 3'.8" 3'.5" 3'.3" 2'.11" <br />Load Width 2" x 2" x 0.036" <br />5' 6'.9" 6'-3" 5'.10" 5'.6" 4'.11" <br />6' 6'.2" 5'.8" 5'.4" 5'.0" 4'.6" <br />7' 5'.9" 5'.3" 4'.11" 4'.8" 4'.2" <br />8' 5'.4" 4'.11" 4'.7" 4'.4" 3'.11" <br />9' 5'.1" 4'.8" 4'.4" 4'.1" 3'.8" <br />10' 4'.9" 4'.5" 4'.1" 3'.10" 3'.6" <br />11' 4'.7" 4'.3" 3'.11" 3'.8" 3'.4' <br />12' 4'.4" 4'.0" 3'.9" 3.6' 3'.2' <br />Load Width 2" x 2" x 0,044" <br />5' 7'.5" 6'.10" 6'.4 . 5'.11" 5'.5" <br />6' 6'.9" 6'.3" 5'.10" 5'.6" 4'.11" <br />7' 6'.3" 5'.9" 5'.4" 5'.1" 4'.7" <br />8' 5'.10" 5'.5" 5'.0" 4'.9" 4'.3" <br />g' 5'.1" 4'.9" 4'.5" 4'.0" <br />10' 5'-3" I 4'.10" 4'-6" 4'.3" 3'.10" <br />11' 4'.11" I 4'.7" 4'.3" 4'.0" 3'.8" <br />12' 4'.9" I 4'.5" 4'.1" 3'.10" 3'.6" <br />Load Width 2" x 2" x 0.055" <br />5' 8'.1" 7'.5" 6'-11" 6'.6" 5'.11" <br />6' 7'.5" 6'.10" 6'-4" 5'.11" 5'.5" <br />7' 6'.10" 6'-4" 5'.10" 5'.6" 4'.11" <br />8' 6'.5" 5'.11" 5'-6" 5'.2" 4'.8" <br />g' 6'.0" 5'.7" 5'.2" 4'.10" 4'.5" <br />10' 5'.9" 5'.3" 4'.11" 4'.7" 4'.2" <br />11' 5'.5" 5'.0" 4'.8" 4'.5" 3'.11" <br />12' 5'.3" 4'.10" 4'.6" 4'.3" 3'.10" <br /> <br />Example: <br />For 2" x 2" x 0,044" Extrusion beam span IS dIstance between uprights. to enter table roof panel projection of <br />14'.0" find load width: <br />LW = 14'12 + 2' OH = 9' Enter table on left under load width. Load Width = 9'.0" Read span under <br />appropriate load: <br />live Load @ 17 # 1 Sq,Ft. 1102 M,P.H. Load Beam Span = <br />Note: <br />Glass Rooms The addition of aluminum frame windows with glass panes that are designed to 110M. P H <br />Wind load requirements to the above upright sizes increases the strength so that additional framing is not <br />required Tables assume extrusion oriented with longer extrusion dimension parallel to applied load. <br /> <br />5'.6" <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER. DEVELOPMENT CONSUL TANT <br />P.O, BOX 4368, SOUTH DAYTONA, FL 32121 <br />TELEPHONE (904) 767-4774 <br />FAX (904) 767.6556 <br /> <br />@ COPYRIGHT 1999 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, PE <br /> <br />, <br /> <br />SECTION 3 <br /> <br />SEAL <br /> <br />PAGE <br /> <br />89 <br />