Laserfiche WebLink
<br />401.------GLAZING--ZONE <br />Elevation Type <br /> <br />BUILDING ENVELOPE SYSTEMS COMPLIANCE <br />CHECK <br /> <br />1------------------------------------------------v- <br /> <br />U SC VLT Shading Area (Sqft) <br /> <br />North <br />East <br />West <br /> <br />Conunercial <br />Conunercial <br />Commercial <br /> <br />402.------WALLS--ZONE <br />Elevation Type <br /> <br />0.55 .22 .75 Continuous Ove 198 <br />0.55 .22 .75 Continuous Ove 248 <br />0...55 .22 .75 Continuous OVe 20 <br />Total Glass Area in Zone 1 = 466 <br />Total Glass Area = 466 <br /> <br />1------------------------------------------------ <br /> <br />U Insul R Gross (Sqft) <br /> <br />--------- -------------------------------- ----- ------- ._---------- <br /> <br />East <br />West <br />North <br />South <br /> <br />BLOCK <br />BLOCK <br />BLOCK <br />BLOCK <br /> <br />403.------DOORS--ZONE <br />Elevation Type <br /> <br />.08 14 1320 <br />.08 14 1320 <br />.08 14 1632 <br />.0814 1632 <br />Total Wall Area in Zone 1 = 5904 <br />Total Gross Wall Area = 5904 <br /> <br />1------------------------------------------------ <br /> <br />U Area (Sqft) <br /> <br />--------- ------------------------------------------ ----- ---------- <br /> <br />Northeast <br />South <br />West <br /> <br />1/4 GLASS <br />1-3/4 Steel <br />1-3/4 Steel <br /> <br />404.------ROOFS--ZONE <br />Type <br /> <br />STOREFRONT .75 42 <br />Door-polyurethane core (18 0.29 21 <br />Door-Polyurethane core (18 0.29 21 <br />Total Door Area in Zone 1 = 84 <br />Total Door Area = 84 <br /> <br />1------------------------------------------------ <br /> <br />Color U Insul R Area (Sqft) <br /> <br />------------------------------------ ------ ----- ------- ---------- <br /> <br />JOIST Medium .06 14 14960 <br />Total Roof Area in Zone 1 = 14960 <br />Total Roof Area = 14960 <br /> <br />405.------FLOORS-ZONE 1------------------------------------------------ <br /> <br />Type Insul R Area (Sqft) <br /> <br />-------------------------------------------~---- <br /> <br />Slab on Grade/Uninsulated 0 14960 <br />~otal Floor Area in Zone 1 = 14960 <br />Total Floor Area = 14960 <br /> <br />406.------INFILTRATION-------------------------------------_____________ <br /> <br />I CHECK <br />Infiltration Criteria in 406.1.ABCD have been met. <br /> <br />MECHANICAL SYSTEMS <br /> <br />CHECK <br />----~~~-i~~d-~i~i~~-~~~-~~~~-~~;f~~~d~-(~~;~~~~~)-------------1----- <br /> <br />407.------COOLING SySTEMS----------------------------------------------_ <br /> <br />Type No Efficiency IPLV Tons <br /> <br />---------------------------- <br /> <br />---------- ----- -------------- <br /> <br />1. Air Cooled ( >= 65,000 Btu/h 1 10 7.5 41.00 <br />408.------HEATING SYSTEMS----------------~---------~---------------_____ <br />Type No Efficiency BTU/hr <br /> <br />-------------------------------- <br /> <br />1. Electric Resistance 1 1.0 286692 <br /> <br />409.------VENTILATION--------------------------------------_____________ <br /> <br />I CHECK <br />