My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
00-9167
Zephyrhills
>
Building Department
>
Permits
>
2000
>
00-9167
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 4:15:44 PM
Creation date
9/6/2006 3:17:46 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
00-9167
Building Department - Name
PARTNERS LIMITED
Address
6429 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />STANDARD LOAD OUTPUTS . , <br />Company Name: COLWILL ENGINEERING 05-20-99 <br />Block Load vl.O Page 1 of 2 <br />************************************************************************ <br />Zone Name: WALGREENS ZEPHRHI <br /> <br />City Name <br />Latitude (deg): <br />Elevation (ft): <br />Indoor -Summer: <br />-Winter: <br /> <br />TAMPA <br />28 <br />35 <br />76 F <br />72 F <br /> <br />50 RH <br /> <br />*, FLORIDA <br /> <br />Weight <br />(lb/sqft) <br /> <br />- Wall: <br />Roof: <br />Bldg: <br />- Wall: <br />Roof: <br /> <br />30 <br />10 <br />30 <br />MEDIUM <br />LIGHT <br /> <br />Color <br /> <br />------------------------------------------------------------------------ <br /> <br /> TEMP TOTAL TONS RSH TONS CFM <br />1. FEB at 9 A.M. 71.2 25.70 17.91 9,302 <br />2 . APR at 10 A.M. 78.6 30.06 18.61 9,667 <br />3 . MAY at 2 P.M. 91.0 35.57 21.17 10,995 <br />4. JUN at 5 P.M. 92.0 38.33 22.14 11,501 <br />5. JUL at 5 P.M. 93.0 38.43 22.24 11,554 <br />6. AUG at 5 P.M. 93.0 38.40 22.21 11,536 <br />7. NOV at 11 A.M. 77.6 29.45 18.74 9,733 <br />Heating Load (Btuh)= 63,804 w/Infil.= 63,804 Airflow= 1,526 cfm <br />--------------------------------------------------------_.~-------------- <br /> <br />ORIENTATION OF BUILDING <br />TRANSMISSION FACTORS <br />Glass Fac.:0.55 Lights <br />Length: 136 Width: <br /> <br />N S <br />0.08 0.08 <br />Fluorescent? Y <br />110 Height: <br /> <br />E W RF <br />0.08 0.08 0.05 <br />Shade Fac.:0.22 Floors: 1 <br />12 Vent Air Percent: 23 <br /> <br />--------------------------~--------------------------------------------- <br /> <br />Number of people = <br />Total lights = <br />Other electrical = <br />Area of N glass = <br />Area of S glass = <br />Area of E glass = <br />Area of W glass = <br />Glass shade area = <br />Total glass area = <br /> <br />Area of N wall = <br />Area of S wall = <br />Area of E wall = <br />Area of W wall = <br />Total wall area == <br />Area of roof = <br />Safety factor = <br />Supply fan hp = <br />Ventilation cfm = <br /> <br />Total cfm-std air= <br /> <br />200 <br />31,416 <br />11,220 <br />200 <br />o <br />246 <br />20 <br />3 <br />466 <br /> <br />1,432 <br />1,632 <br />1,074 <br />1,300 <br />5,438 <br />14,960 <br />0% <br />6.62 <br />2,250 <br /> <br />11,554 <br /> <br />Sensible people load = <br />Lighting load = <br />Other electrical = <br />North glass solar = <br />South glass solar = <br />East glass solar = <br />West glass solar = <br />Glass shade solar = <br />Total glass solar = <br />Total glass trans. = <br />N wall load = <br />S wall load = <br />E wall load = <br />W wall load = <br />Total wall trans. = <br />Roof load = <br />Safety load = <br />Fan heat gain (DT) = <br />Vent sensible load = <br />Vent latent load = <br />People latent load = <br />Total latent load == <br /> <br />Room sensible = 266,898 Room latent <br />Plenum return exhaust credit = 0 <br />--> GRAND TOTAL LOAD = 461,204 Btu/hr or <br />Load run f.or # 5. JUL at <br /> <br />Area (sq ft) = 14,960 Sq ft/ton <br />Total cfm-std air= 11,554 Cfm/sq ft <br />HEATING LOAD <br /> <br />49,000 <br />134,029 <br />38,294 <br />821 <br />o <br />897 <br />586 <br />12 <br />2,315 <br />4,357 <br />2,062 <br />2,676 <br />1,630 <br />4,282 <br />10,651 <br />28,230 <br />o <br />20,288 <br />42,075 <br />90,943 <br />41,000 <br />131,943 <br /> <br />= 41,000 <br /> <br />38.43 tons <-- <br />5 P.M. <br /> <br />= <br /> <br />389 <br />0.77 <br /> <br />= <br /> <br />------------------------------------------------------------------------ <br /> <br />Ventilation load = 91,575 <br /> <br />Roof heating load <br /> <br />= <br /> <br />27,676 <br />