Laserfiche WebLink
<br />ATTACHED & FREESTANDING COVERS AND UTILITY SHEDS <br /> <br />SECTION 2 <br /> <br />2'-0" MIN. <br />BEFORE SLOPE ~ <br />r 1v ~ <br /> <br />(1) #5 BAR CONT. <br /> <br />TYPE I <br />FLAT SLOPE / NO FOOTING <br />0-2" /12" <br /> <br />(1) #5 BAR CO NT. <br /> <br />~ <br />~ .' <br />- ,.-.~.--, <br />Co >'~:.,,: .. . <br /> <br />8" <br />TYPE II <br />MODERATE SLOPE FOOTING <br />2" / 12" - 1'-1 0" <br /> <br /> <br />. <br />N <br />..... <br /> <br />~ . :,,:)~.~~:":"""";"''''' <br />./ .~.. .. <br />.' . ~.. A,' <br /> <br />1'-0" <br />TYPE III <br />STEEP SLOPE FOOTING <br />> 1'.10" <br /> <br />NOTES: <br />1. NO FOOTING REQUIRED EXCEPT WHEN ADDRESSING EROSION UNTIL THE COMBINED BEAM <br />LENGTH AND UPRIGHT HEIGHT OF THE ENCLOSURE EXCEEDS 55'-0" THEN A TYPE II <br />FOOTING IS REQUIRED. <br /> <br />2. MONOLITHIC SLABS AND FOOTINGS SHALL BE MINIMUM 2,500 PSI CONCRETE WITH 6x6-10x10 <br />WELDED WIRE MESH OR FIBER MESH MAY BE USED IN LIEU OF MESH. <br /> <br />3. IF LOCAL BUILDING CODES REQUIRE A MINIMUM FOOTING USE TYPE II FOOTING OR <br />FOOTING SECTION REQUIRED BY LOCAL CODE. LOCAL CODE GOVERNS. <br /> <br />SLAB-FOOTING DETAILS <br />SCALE: 1/2" = 1'-0" <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER. DEVELOPMENT CONSUL TANT <br />PO. BOX 4368, SOUTH DAYTONA, FL 32121 <br />TELEPHONE (904) 767.4774 <br />FAX (904) 767.6556 <br /> <br />SEAL <br /> <br />@ COPYRIGHT 1999 <br />NOT 10 BE REPRODUCED IN WHOLE OR IN PART WIlHOUTTHE WRIITEN PERMISSION OF LAWRENCE E. BENNETI, P.E <br /> <br />PAGE <br /> <br />59 <br />