<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />I ADDRESS:...
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br />COMPONENTS SECTION I REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Exterior Windows & Doors 606.1.ABC.1.1 ! Maximum:,3 cfm/so,ft, window area' .5 cfm/so.ft. door area,
<br />Exterior & Adjacent Walls 606,1,ABC.1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> i
<br /> ! ! penetrations; between wall panels & top/bottom plates; between walls and floor. I
<br /> I EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from and is sealed to the foundation to the too olate,
<br />Floors 606.1.ABC.1 .2.2 , Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the oerimeter oenetrations and seams.
<br />Ceilings 606.1.ABC,1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> , attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> I
<br /> , installed that is sealed at the nerimeter at oenetrations and seams.
<br />Recessed Lighting Fixtures 606.1.ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br /> conditioned soace tested,
<br />Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavity between floors. I
<br />Additional Infiltration reqts 606,1,ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br /> have combustion air.
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.\
<br />COMPONENTS SECTION I REQUIREMENTS CHECK
<br />Water Heaters 612,1 I Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
<br /> i breaker (electric) or cutoff (cas) must be orovided, External or built-in heat trao reauired.
<br />Swimming Pools & Spas 612,1 I Spas & heated pools must have covers (except solar heated). Non-commercial pools
<br /> I ! must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br /> i efficiency of 78%,
<br /> !
<br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 oallons oer minute at 80 PSIG,
<br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610,
<br /> i Ducts in unconditioned attics: R-6 min, insulation,
<br />HVAC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each svstem.
<br />Insulation 1604.1,602.1 Ceilings-Min. R-19, Common walls-Frame R-11 or CBS R-3 both sides,
<br /> I Common ceiling & floors R-11,