Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:... <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION I REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 ! Maximum:,3 cfm/so,ft, window area' .5 cfm/so.ft. door area, <br />Exterior & Adjacent Walls 606,1,ABC.1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> i <br /> ! ! penetrations; between wall panels & top/bottom plates; between walls and floor. I <br /> I EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the too olate, <br />Floors 606.1.ABC.1 .2.2 , Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetrations and seams. <br />Ceilings 606.1.ABC,1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> , attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> I <br /> , installed that is sealed at the nerimeter at oenetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned soace tested, <br />Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavity between floors. I <br />Additional Infiltration reqts 606,1,ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.\ <br />COMPONENTS SECTION I REQUIREMENTS CHECK <br />Water Heaters 612,1 I Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> i breaker (electric) or cutoff (cas) must be orovided, External or built-in heat trao reauired. <br />Swimming Pools & Spas 612,1 I Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> I ! must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> i efficiency of 78%, <br /> ! <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 oallons oer minute at 80 PSIG, <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br /> i Ducts in unconditioned attics: R-6 min, insulation, <br />HVAC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each svstem. <br />Insulation 1604.1,602.1 Ceilings-Min. R-19, Common walls-Frame R-11 or CBS R-3 both sides, <br /> I Common ceiling & floors R-11, <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-97 <br /> <br />EnergyGauge@/FlaRES'97 F LR C NA-200 <br />