Laserfiche WebLink
<br />ATTACHED & FREESTANDING COVERS AND UTILITY SHEDS <br /> <br />w <br />~ <br />o <br />:r: <br />w <br />..J <br />CD <br />o <br />~ <br />(!) <br />z <br />i= <br />~ <br />>< <br />w <br /> <br /> <br />SECTION 2 <br /> <br />PAN OR COMPOSITE PANEL <br />(SEE TABLES SECTION 7) <br /> <br />TOP PLATE PT OR WI VAPOR <br />BARRIER @ ALUMINUM ROOF <br /> <br />2 x 4 TOP PLATE @ ROOF <br /> <br />2 x 2 ALUMINUM OR 2 x 4 LUMBER #2 <br />SPF (MIN,) <br /> <br />SHEATHING: 7/16" O,S.8, OR 1/2" <br />PLYWOOD WI STUDS 24" O.C, OR <br />STRUCTURAL GRADE THERMAL PLY <br />WI STUDS@ 16" O,C, <br /> <br />2 x 4 PRESSURE TREATED PLATE WI <br />3/8" x 4-1/2" CONCRETE ANCHORS @ <br />4'-0" 0 C, (SEE SLAB DETAILS) <br />ATTACH SHED OR ROOM WALL TO <br />HOST STRUCTURE WI 1/4" x 3-1/4" <br />TAPCONS @ 16" O,C, FOR MASONRY <br />OR #16d COMMON @ 16" O,C, OR #10 X <br />3-1/2" FOR WOOD OR #10 X 2-1/2" <br />S,M,S, FOR 1 X 2 ALUMINUM OR #10 X <br />3-112" S.M,S, FOR 2 X 2 ALUMINUM <br />SHED IS FRAMED FOUR WALL <br />STRUCTURE OR ATTACHED TO HOST <br />MAXIMUM FLOOR AREA 200 SQ, FT <br />FLOOR AREA GREATER THAN 200 SQ, <br />FT, USE SECTION 4 <br /> <br />POST AND BEAM DETAILS AND <br />TABLES SECTION 2 <br />FOOTING AND CONNECTION DETAILS <br />SECTION 2 <br /> <br />UTILITY SHED AND CARPORT WALL SECTION <br /> <br />SCALE: 1/4" = 1'-0. <br /> <br />SHEDS AND UTILITY ROOMS BUILT UNDER SECTION 2 SPECIFICATIONS SHALL BE LIMITED TO <br />16 FT IN ROOF SPAN DIRECTION AND 200 SQ, FT MAXIMUM AREA <br />2, ALL WOOD FRAMING AND SHEATHING CONNECTIONS SHALL BE IN COMPLIANCE WITH STANDARD <br />CODE 1997 CHAPTER 23. TABLE 2306.1 OR AS NOTED BELOW, <br /> <br />CONNECTION FASTENER NUMBER I SPACING <br />WALL SHEATHING 1/2" OR LESS #6 COMMON 6" O,C, EDGES AND 12" O,C, FIELD <br />TOP OR SOLE PLATE TO STUD <br />A. END NAIL #16 COMMON 2 <br />B, TOE NAIL #8 COMMON 2 <br /> <br />SEE CONNECTION DETAILS <br />(SECTION 7) <br /> <br />~ <br /> <br />w <br />~ <br />o <br />:r: <br />w <br />..J <br />CD <br />o <br />~ <br />(!) <br />Z <br />I- <br />C/) <br />>< <br />w <br /> <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL TANT <br />PO BOX 4368, SOUTH DAYTONA. FL 32121 <br />TELEPHONE (904) 767-4774 <br />FAX (904) 767-6556 <br /> <br />SEAL <br /> <br />@ COPYRIGHT 1999 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E BENNETT, P E <br /> <br />SEE CONNECTION DETAILS <br />(SECTION 7) <br /> <br />12" X PAN (SEE TABLES SECTION 7) USE 'W' <br />TO SELECT PAN FOR REQUIRED SPAN <br /> <br />- 'W1' VARIES-, <br /> <br />FOR FRONT BEAM USE L = WI 2+0VERHANG <br /> <br />PAGE <br /> <br />55 <br />