Laserfiche WebLink
<br />AO'OITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.18 HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HeM) <br />Programmable Thermostat HCM ,95 <br />Muttizone HCM ,95 <br /> -- ----" - I I I I I ,93 & Uo <br />Natural Gas AFUE ,68-.72 ,73,,77 ,78-,82 ,83-,87 .88-,92 <br /> HCM --~--J~~--i- :~-'l .49 I .46 I ,44 I ,4t <br /> ---- ----~--~_.~--- -,,-- -_.._.._~ I I ,55 I <br />LP Gas HCM ,62 ,58 .52 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />_SYSTEM r.'!~___,___ ___~_QL!NG CR~Q1,IMUL TIP.hIERS t~~_ <br />Ceiling Fans ,_,_,~_ <br />Cross Ventilation ,95' <br />_._---~------_.- <br />Whole House Fan ,_,_,__ _, ,95. <br />Multizone ,__, ,95 <br />Programmable Thermostat ,95 <br /> <br />.Credit may be taken for only <br />one of Ihese system types concurrently, <br /> <br />6A-20 HOT WATER CREDIT MULTIPLIERS (HWCM) <br />____,_J;"ySlE.MJJPE NOTE: A HWM MUST BE USED IN CONJUNCTION WITH All HWCM, SEE TABLE 6A,9, EF MEANS ENERGY FACTOR. <br /> <br /> <br />::=:""" =:!~=>i__ =--=-_-t=--=-=~2A9 ^' ["- 252~. 3H49 "'T' 3'~ ~ <br />5;W~"H"", =~~=::=== i-=~l' =- ~~~ ==~= '~9291 '';;' : 'O:7~ <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH All HWCM, SEE TABLE 6A,9, EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Extenor Windows & Doors 606,1,ABC,1,1 Max: ,3 cfm/sq,ft. window area; ,5 cfm/sq.ft. door area, <br />Exterior & Adjacent Walls 606,1,ABC,1.2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & top/bottom plates; between walls & floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the top plate. <br />Floors 606,1,ABC,1,2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams, <br />Ceilings 606,1,ABC,1.2,3 Seal: Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, ch~ ses, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> allic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams, <br />Recessed Lighting Fixtures 606,1.ABC,1.2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with <2,0 cfm from <br /> conditioned space tested. <br />Multi-story Houses 606,1,ABC,1,2,5 Air barrier on perimeter of floor cavity between floors. <br />Additional Infiltration reqts 606,1,ABC.l,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air, <br /> <br />6A.22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be provided, External or built-in heat traD reauired, <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiencv of 78%. <br />Shower Heads 612,1 Water flow must be restricted to no more than 2,5 gallons per minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned <br /> attics: R-6 min, insulation. <br />HV AC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system. <br />Insulation 604,1,602,1 Ceilinos-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, Common ceilino & floors R-11. <br /> <br />-6, <br />