Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:, ZEPHYRHILLS, FL, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />~QIIJI..P9NENTS.~..__ SECTION gEQUIREMENTS FOR EACH PRACTICE -~--'--~.~._~.-- CHECK <br />....-.-- .-.-- <br />Exterior Windows & DOOf\S_ f-~1,ABC,1,1 .. Maximum:,3 cfm/sq,ft, window area; ,5 cfm/sq,ft, door area, -. <br />Exterior & Adjacent Walls 606,1,ABC,1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> ~- -~ from and is sealed to, the foundation to the top plate, <br />- <br />Floors 606,1,ABC,1,2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />-_.~._------~.- ----~ .~--_. to the oerimeter, penetrations and seams, -_._~ <br />Ceilings 606,1 ,ABC,1 ,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />" --_._~_.._-------_..~~---------+---"_.__._-- ~.._.- 1l1sta~d that is sealed at th~~imeter, at penetrations and seal'Yl~-,--,_~__________ f--._- <br />Recessed Lighting Fixtures 606,1,ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non~IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br />-- --- f- ... conditioned space, tested, ._____~~_.__~__________._ <br />~~:,~:.~~, req~-::~:~~~5- 6irJ~~rrier on perimeter of floor cavity between floors, __~__ <br />Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />haye combustion air. _. .'. .... <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences,) <br />COMPONENTS -------_.-- ~CTION REQUIREMENTS .~_.~------_._~----_..~_._---- CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit <br />---_._._-----.-..,---_._._._-~_._---- I--._-~-_._-_. Jlr.e~ker. (electric:l..QI: cutoff ~l.r1'1~st be provided, External or built-in tJeat tr~~quirecL____ f------ <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%, <br />Shower heag~____ T61~~_~_,--Water flow must be restricted to no more than 2,5 gallons per minute at 80 PSIG, -==i=-- <br />Ale D"'bul'" S}'$lom' I 61D.' All d_, 00'"" mooh..'"" """'pm"" ..d p',""m '_b,~ 'h.lI bu mOOh"'",", <br />-- -____ _ r- __ . r:;.",::;;:~":;:'~~:~~,;";=d.." with '''' """~_Of S"':~61D. ..1__ <br />HVAC ,Controls..________t607,.1__~_.__ ~~i:lrate readily accessible manual or automatic thermostat for each s~~.Ill..._ . <br />Insulation 1604.1,602,1 Cellings-Mln, R-19, Common walls-Frame R-11 or CBS R-3 both sides <br /> I ' <br /> I I Common ceiling & floors R-11, <br />