<br />FORM 600A-97
<br />
<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />I ADDRESS:, ZEPHYRHILLS, FL,
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />PERMIT #:
<br />
<br />~QIIJI..P9NENTS.~..__ SECTION gEQUIREMENTS FOR EACH PRACTICE -~--'--~.~._~.-- CHECK
<br />....-.-- .-.--
<br />Exterior Windows & DOOf\S_ f-~1,ABC,1,1 .. Maximum:,3 cfm/sq,ft, window area; ,5 cfm/sq,ft, door area, -.
<br />Exterior & Adjacent Walls 606,1,ABC,1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & toplbottom plates; between walls and floor.
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> ~- -~ from and is sealed to, the foundation to the top plate,
<br />-
<br />Floors 606,1,ABC,1,2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members,
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br />-_.~._------~.- ----~ .~--_. to the oerimeter, penetrations and seams, -_._~
<br />Ceilings 606,1 ,ABC,1 ,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br />" --_._~_.._-------_..~~---------+---"_.__._-- ~.._.- 1l1sta~d that is sealed at th~~imeter, at penetrations and seal'Yl~-,--,_~__________ f--._-
<br />Recessed Lighting Fixtures 606,1,ABC,1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non~IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br />-- --- f- ... conditioned space, tested, ._____~~_.__~__________._
<br />~~:,~:.~~, req~-::~:~~~5- 6irJ~~rrier on perimeter of floor cavity between floors, __~__
<br />Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br />haye combustion air. _. .'. ....
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences,)
<br />COMPONENTS -------_.-- ~CTION REQUIREMENTS .~_.~------_._~----_..~_._---- CHECK
<br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit
<br />---_._._-----.-..,---_._._._-~_._---- I--._-~-_._-_. Jlr.e~ker. (electric:l..QI: cutoff ~l.r1'1~st be provided, External or built-in tJeat tr~~quirecL____ f------
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br /> efficiency of 78%,
<br />Shower heag~____ T61~~_~_,--Water flow must be restricted to no more than 2,5 gallons per minute at 80 PSIG, -==i=--
<br />Ale D"'bul'" S}'$lom' I 61D.' All d_, 00'"" mooh..'"" """'pm"" ..d p',""m '_b,~ 'h.lI bu mOOh"'",",
<br />-- -____ _ r- __ . r:;.",::;;:~":;:'~~:~~,;";=d.." with '''' """~_Of S"':~61D. ..1__
<br />HVAC ,Controls..________t607,.1__~_.__ ~~i:lrate readily accessible manual or automatic thermostat for each s~~.Ill..._ .
<br />Insulation 1604.1,602,1 Cellings-Mln, R-19, Common walls-Frame R-11 or CBS R-3 both sides
<br /> I '
<br /> I I Common ceiling & floors R-11,
<br />
|