Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Residential Whole Building Performance Method A <br />"" . 1__.....__ ___ <br />.Lew.LS '~~::~~::~:.._ <br />I ~~~~"::'l'.LNI,j <br />,~:.:!::::;..- <br />I 1:' j:!;KjYl.L 'l' N U . <br /> <br />rUKlVl 600A-93 <br />PROJECT NAiviE; <br />AND ADDRESS; <br /> <br />OWNER; <br /> <br />1. New construc~.Lon or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units <br />4. If Multifamily, is this a worst case (yesino) <br />5. Conditioned floor area (sq.ft.) <br />6. Predominant eave overhang (ft.) <br />7. Porch overhang length (ft.) <br />8. Glass area and type; <br />a. Clear Glass <br />b. Tint, film or solar screen <br />9. Floor type and insulation; <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation; <br />a. Exterior; 2. Wood frame (Insulation R-value) <br />b. Adjacent; 2. Wood frame (Insulation R-value) <br />11.Ceiling type area and insulation; <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />14.Heating System; <br /> <br />15.Hot water system; <br /> <br />16.Hot Water Creu.L~S; (HR-Hea~ Kecovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice; 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />SN; 8132 <br /> <br />CENTRAL <br /> <br />1_... _......_...... <br />I I..;L.L1VlA'.L' j:!; <br />- _.......... .. I I __ I I _ I I <br />'~~~~:_~1=1_~1~1 bl_1 <br />10UK.L~U.LI..;'l'.LUN NU. <br /> <br />CK <br /> <br />1. New Const.ruction <br />2. Single-Family <br />3. 0 <br />4. <br />5. 1385.50 <br />6. 1. 00 <br />7. 8.00 <br />Single Pane <br />8a. O.Osqft <br />8b.183 .1sqft~ <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 0.00 " 162.60 ft <br /> <br />10a-2 R=l1. 00, 1379. 60sqft_ <br />10b-2 R=l1. 00, 175. 20sqft_ <br /> <br />lla.R=30.00 , 1385.50sqft_ <br /> <br />12a. R= 6.00 uncond <br />13. Type; Central AiC <br />SEER; 10.00 <br />14. Type; Heat Pump <br />HSPF; 6.60 <br />15. Type; Electric <br /> <br />EF; 0.88 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />CF CV <br /> <br />19. <br />19a. <br />19b. <br /> <br />83.62 <br />22125.62 <br />26458.19 <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553 . 908, F. S . <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are i~ ~ian with the <br />Florida Enargy Cod . <br />, <br /> <br /> <br />I hereby cer~.Lry ~nat ~nis bU.L.Lu.Lng is <br />in compliance with the Florida Energy <br />Code. .----:?/~/"./ /' <br /> <br />OWNERiAGENT; ~/~H'~~ <br />DATE; f-~y-~.> <br /> <br />BUILDING~A~~' - <br />DATE; 1 ~ <br />