Laserfiche WebLink
<br />Department OL ~ommun~~y Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />l' <br />.t'UKlVJ. 600A-93 Residential Whole Building Performance Method A CENTRAL <br />PROJECT NAME; JAMMAR -- 'BUILDER: <br />AND ADDRESS: t-l-\ ~'" l(\-)Vl{ii'~ p I ~E~~~TING~ /7~ or I ~~~~T~ I ~ _ I I <br />___ .2" . '..I._e>~~:.:-:!::~?1I9.RP'/LLS I~~~:,.:. ;l~~I:-:l bl_1 <br />uW.N'ER: 0 1.P.t;.t{1VI~'l.' ~u. 955/./3 IlJU.tC.H)D~~'l.'~U~ ~u.t//,~~ <br />~---- ~K <br />1. New construction or aaa~~~on 1. ~ew Construction <br />2. Single family detached or Multifamily attached 2. Single-Family <br />3. If Multifamily-No. of units 3. 0 <br />4. If Multifamily, is this a worst case (yesino) 4. <br />5. Conditioned floor area (sq.ft.) 5. 1341.00 <br />6. Predominant eave overhang (ft.) 6. 1.30 <br />7. Porch overhang length (ft.) 7. 0.00 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a. O.Osqft <br />b. Tint, film or solar screen 8b.153.4sqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) 10a-l R= 5.00, 744.80sqft____ <br />b. Adjacent: 2. Wood frame (Insulation R-value) 10b-2 R=11.00, 170.20sqft____ <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />SN: <br /> <br />8132 <br /> <br />Double .pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 0.00 , <br /> <br />140.50 ft <br /> <br />lla.R=22.00 , <br /> <br />1341.00sqft____ <br /> <br />14.Heating System: <br /> <br />12a. R= b.UU uncond <br />13. Type: Central AiC <br />SEER: 10.00 <br />14. Type: Heat Pump <br />HSPF: 6.60 <br />15. Type: Electric <br /> <br />15.Hot water system: <br /> <br />16.Hot wa~er Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />EF: 0.88 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br />CF CV <br /> <br />19. <br />19a. <br />19b. <br /> <br />86.68 <br />24759.75 <br />28564.54 <br /> <br />------------------------------------------------------------------------------- <br /> <br />------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Florida Energy Code. <br /> <br />P~~!'.'1!]1~-l?-; \. ~ ~ <br />DinE!> 0 0 <br />.: ,. l' i <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />I herebYi,.pertify ~nat ~n~s bu~~a~ng ~s <br />in compliance with the Florida Energy <br />Code. ~ <br /> <br />g~~~~/~~ ~~~ ~ <br /> <br />BUILDING <br />DATE: <br /> <br />OF~I/IAL/~~1 <br />~ /' 2 t <br />