<br />TABLE 6B-1 <br /> <br />MINIMUM REQUIREMENTS <br /> <br />COMPONENTS PACKAGES FOR NEW CONSTRUCTION <br /> A I B C 0 E F <br /> Max,%ol glass to Floor Area 15% 15% 20% 20% 25% 25% <br /> en Double 'Tint (01) <br /> en Type Double Clear (DC) Single 'Tint (S1) Double Clear (DC) Single 'Tint (51) Double 'Tint (01) <br /> :5 <br /> c:J Overhang 2' 1'4' 2' 2" 2" 2' <br /> Masonry EXTERIOR AND ADJACENT MASONRY WALLS R-5 <br />en COMMON MASONRY WALLS R-3 EACH SIDE. <br />...J <br />...J <br />< <br />3 Wood EXTERIOR, ADJACENT, AND COMMON WOOD FRAME <br /> Frame WALLS R-11 <br />CEILINGS CEILINGS UNDER ATTIC R-30. FRAME COMMON CEILINGS R-11. <br /> (NO SINGLE ASSEMBLY CEILINGS ALLOWED) <br />en Slab-On-Grade R-O <br />a: <br />0 Raised Wood R-11 (ONLY STEM WALL CONSTRUCTION ALLOWED EXCEPT PACKAGE D) <br />9 Raised Concrete R-5 <br />u. <br />DUCTS R-6 R-6 R-6 R-6 R-6 R-6 <br />SPACE COOLING (SEER) 12.0 10,0' 10.0' 12.0 10.0' 10.9 <br />~ Elect. STRIP 6,8' 6,8' 7.4 6.8' 7.6 <br />W Gas/Oil (AFUE) MINIMUM OF .73 (Direct heating) or .78 (Central) <br />:I: <br />a: Electric EF .90 EF .90 EF .90 NOT ALLOWED NOT ALLOWED EF.90 <br />w;:a Resistance ** (SEE BELOW) (SEE BELOW) <br />~W <br />3~ Gas & Oil ** MINIMUM EF OF ,54 NATURAL GAS ONLY <br />1->- (SEE BELOW) <br />Oen <br />:I: Other Any of the following are allowed: dedicated heat pump, <br /> heat recovery unit or solar system. <br /> <br />Climate Zones 4 'S 6 <br />TO BE INSTALLED <br /> ':J- % <br />DC: 0 DT: 0 <br /> FEET <br />00: R= <br />AOJ: R= <br />COM: R= <br />00: R= <br />AOJ: R= II <br />COM: R= <br />UNDER ATTIC: R = <br />COMMON: R = <br />R= f) <br />R= <br /> 0 <br /> )t c/(,.;> <br />AFUE = <br />EF= , S' <br />EF= <br />DHP: EF= <br />HRU: 0 <br />SOLAR: EF= <br /> <br /> <br />Single package units mirnmum SEER:9,7, HSPF = 6,6, <br />Minimum effICiencies for gas and electric hot water systems apply to to 40 gallon water heaters. Refer to Table 6- 12 for minimum Code efficiencies for oil water heaters and other sizes, <br /> <br />DESCRIPTION OF BUILDING COMPONENTS USTED <br />Percent of Glul to Floor Area: This percentage is calculated by dividing the total of all glass areas by the total conditioned floor area. <br />Overhang: The overhang is the distanCe the roof or soffit projects out horizontally from the face of the glass. All glass areas shall be under an overhang of at least the prescribed length with the following exceptions: 1) giass <br />on the gabled ends of a house and 2) the glass in the lower stories 01 a mutli-story house, <br />Wall, Ceiling and Floor Insulation Val...: The R.vaIues indicated represent the minimum acceptable insulation level added 10 the structural components of the wall, ceulng or floor, The R-value of the struclural building <br />materials shaU not be included in this calculation, "Common' components are those separating conditioned tenancies in a multifamiiy building, . Adjacent' components separate conditioned space from unconditioned but <br />endosed space, 'Exterior" components separate conditioned space from unconditioned and unenclosed space. <br />Roor: SI~rade floors without edge insulation are acceptable. Raised wood floors shall have continuous stem walls with insulation placed on the stem wall or under the loor except Package D, <br />Ducls: 'COND' indicates that the ducts must be installed within the conditioned space: that is, the ductworX shall be located on the conditioned side of the insulation. Ducts in conditioned space are acceptable for any <br />prescriptive package. <br />Space Cooling System: Cooling systems shall have a Seasonal Energy Efficiency Ratio (SEER) for central units or Energy Efficiency Ratio (EER) for room units or PTAC's equal to or greater than the prescnbed value. <br />Electric Space Heating Option: Heal pump systems shall be rated with a Heating Seasonal Performance Factor (HSPF) equal to or greater than the prescribed HSPF, Heat pump systems may contain electnc stnp backups <br />meeting the criteria of section 608,1.ASC,3,2.1,2, No electric resistance space heat is allowed for these packages. <br />Electric Resistance Hot Wster Option: For packages designated 'Not AJIc1fteff, an etectric resistance hot water system may be installed only in conjunction with one of the 'Other Hot Water System Options'. See below. <br />Other Hot Water System Options: Any dedicated heat pump, heal recovery unit, or solar hot water system may be installed, Solar systems must have an EF of 1.5 or higher, Electric resistance systems having an EF of .88 <br />or greater. or natural gas systems with EF ,54 or greater may be used in conjunction with these systems, <br /> <br />TABLE 6B-21 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS I CHECK <br />Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather-stripped or otherwise sealed. j,.. <br />Exterior Windows & Doors 606,1 Max ,3 elm/sq,jt, window area; ,5 elm/sq.ft. door area. L/ <br />Sole & Top Plates 606,1 Sole plates and penetrations through top plates of exterior walls must be sealed. Iv <br />Recessed Lighting 606,1 Type IC rated with no penetrations (two alternatives allowed). I Jj-fJ <br />Multi-story Houses 606,1 Air barrier on perimeter of Iloor cavity between floors. I A/'r} <br />Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except lor combustion / <br /> devices ~ith integral exhaust ductwork. <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) X <br /> or cutoff (oas) must be orovided, External or built-in heat trao reauired, <br />Swimming 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a vv/l <br />Pools & Soas I pumo timer. Gas spa & 0001 heaters must have minimum thermal efficiencv 01 78%. <br />Hot Water Pipes 612.1 In3ulation is required lor hot water circulatina systems (including heat recovery units). v <br />I <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG, 7 <br />HV AC Duct 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Construction, sealed, insulated and installed in accordance with the criteria 01 Section 610,1. Ducts in attics must be X' <br />Insulation & Installation insulated to a minimum of R-6. Air handlers in attics shall be within 5' of an attic access, have a radiant <br /> barrier installed above the ahu extendino 10' in all directions & meet requirements 01 other codes, <br />HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system, I <br /> <br />-2- <br />