<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:... <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />~xterior WindONS & Doors 606.1,ABC.1.1 Maximum:.3 cfmIsa.ft. window area' .5 cfmlso.ft. door area. <br />Exterior & Adjacent Walls , 606.1,ABC,1.2.1 Caulk, gasket, weatherstrip or-seal between: windONSldoors & frames, surrounding wall; <br /> ! foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> I <br /> i penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> - ---- - ---~..- from and is sealecl to the foundation to the too olate. - <br />Floors 606,1 ,ABC. 1 ,2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />-- --- _.--_..~ . I -.--- . to the nArimeter nAnAtrations and seams. <br />Ceilings 1606.1,ABC.1.2.3 Bel.v.oeen walls & ceilings; penetrations of ceiling plane r:J top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealecl to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />---- -----~-~--_.._-- I installed that is sealed at the oerimeter at ons and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealecl box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />- __.m._... conditioned soace_ tested. <br />.Multi-st9fV Houses 606,1.ABC.1.2.5 Air barrier on oerimeter r:J floor ca\Iitv between floors. ! <br />Additional Infiltration reqts 606,1.ABC.1.3 Exhaust fans liented to outdoors, daTlpers; combustion space heaters comply with NFPA, I <br /> I <br /> I have combustion air. ! <br /> I <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br /> <br />COMPONENTS <br />_._..._-~----- <br />Water Heaters <br /> <br />SECTION <br />612.1 <br /> <br />4- <br />I <br /> <br />I <br /> <br />HV AC Controls <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br /> <br />REQUIREMENTS <br />Comply with efficiency requirements in Table 6-12. Switch or clear1y marked circuit <br />breaker electric or cutoff as must be fOIIidecI. External or built-in heat trap required. <br />Spas & heated pools must have COIIerS (except solar heated). NOl'H:OITImercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />efficien of 78%. <br />Water flow must be restricted to no more than 2.5 allons minute at 80 PSIG. <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealecl, insulated, and installed in accordance with the criteria r:J Section 610. <br />Ducts in unconditioned attics: R~ min. insulation. <br />e readil accessible manual or autanatlc thermostat for each stem. <br />Ceilings-Min. R-19. Common walis-Frame R-11 or CBS R-3 bah sides. <br />Common ceiling & floors R-11. <br /> <br />: CHECK <br />~-_.-+_._--,- <br /> <br />Swimming Pools & Spas <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />EnergyGaugeâ„¢ DCA Form 6OQA-97 <br /> <br />EnergyGaugelB}lFlaRES'97 FLRCNA-200 <br />