Laserfiche WebLink
<br />FROM ALL-AMERICAN HOME-INSPECTORS <br /> <br />PHONE NO, <br /> <br />813 853 2711 <br /> <br />P02 <br /> <br />/~ <br /> <br />ARKAY ENGINEERING, <br />structural <br /> <br />INc. <br /> <br />. <br />engIneers <br /> <br />August 2, 2000 <br /> <br />VARI Construction Servi~A~, Tn~. <br />23110 State Road 54 - #106 <br />Lutz, Florida 33549 <br /> <br />Attention: Frank Vari <br /> <br />Rc: Arlington Revised Hodel - Silver Oaks Villago - Lot #60 <br />pormit #9611 - Arkay Engineering, Inc. Job # 3395 <br /> <br />Dear Mr. Vari: <br /> <br />This letter is to confirm our telephone conversation regarding a field <br />revision to the above referenced project. The building shall be <br />modified as follows: <br /> <br />1) The house will be widened from 44'-8" to 46'-8" on tho garago <br />side (The garage width will increase from 201-6" to 22'-6" and <br />the patio shall widen from 71-0" to 91-0"). <br />2) The extended structure shall be constructed per the "Typical <br />Wall Soction" shown on shoot 2 of tho approved construction <br />plans. <br />3) The foundation of the extended portion of the building shall <br />be tied into the existing foundation with 2-#5 rebars drilled <br />and set in epoxy with a minimum embedment of 6 inches into the <br />side of the existing foundation. <br /> <br />These modificCltioms tlL.~ ~tL-uctuL"tllly acceptable and conform to the 1997 <br />Standard Building Code, Chapter 16, Section 1606 for 100 MPH wind <br />loads. <br /> <br />If you need Clny fUL.th~.r: assistance with this matter, please give me a <br />call. <br /> <br /> <br />Inc. <br /> <br />P.E. <br /> <br />Lakeland. Florida 33809 <br />Fax: 863-816-2118 <br />