Laserfiche WebLink
<br />SECTION 2 <br /> <br />ATTACHED & FREESTANDING COVERS AND UTILITY SHEDS <br /> <br />o <br /> <br />PAN OR COMPOSITE PANEL ROOF <br /> <br />o <br /> <br />o <br /> <br /> <br />CENTER OF J <br />BRACE CONNECTION <br />FOR START OR <br />END OF BEAM SPAN <br /> <br />KNEE BRACE NOT REQUIRED <br />FOR ATTACHED STRUCTURES <br /> <br />KNEE BRACE REQUIRED IF <br />POST NOT SET IN CONCRETE <br />FOOTING <br /> <br />H-CHANNEL KNEE BRACE 2" x 3" X 0.050" KNEE BRACE WI (3) #10 x 1/2" <br />EACH SIDE OF BEAM U-CHANNEL ON SIDE WI (3) #10 x 1/2" AND KNEE <br />BRACE INTO POST AND (3) #10 x 1/2" EACH SIDE OF KNEE BRACE WI <br />CORROSION RESISTIVE WASHER HEADED SCREWS <br /> <br />KNEE BRACE TO POST DETAIL - BEAM PERPENDICULAR TO ROOF <br />'SCALE 1/4" = 1" <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL T ANT <br />PO. BOX 4368, SOUTH DAYTONA, FL 32121 <br />TELEPHONE (904) 767.4774 <br />FAX (904) 767-6556 <br /> <br />SEAL <br /> <br />PAGE <br /> <br />@ COPYRIGHT 1999 <br /> <br />62 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E BENNETT, PE <br />