<br />FORM 600A-97 <br />.. <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br /> <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br /> <br />Arlington Model !;/;/lj/l5/!V/l L~J;>P;' -Builder:-' Vari Homes I <br />Lot: 2J[, Sub: SOV, Plat: PB 1 PG 55 Permitting Office: eJ./;T'I or ~IYI/u.p <br />Zephyrhills, FI 33543- Permit Number: 9~/~,B ! <br />Vari Construction Services Jurisdiction Number: e::, / /? 00 . <br />Central <br /> <br />--. - <br />Project Name: <br />Address: <br />City, State: <br />, Owner: <br />Climate Zone: <br /> <br />I. New construction or existing <br />2. Single family or multi-family <br />3. Number of units, if multi-family <br />4, Number of Bedrooms <br />5. Is this a worst case? <br />6. Conditioned floor area (ft') <br />7. Glass area & type <br />a. Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SC/SHGC - single pane <br />d. Tint/other SC/SHGC - double pane <br />8. Floor types <br />a. Raised Concrete <br />b. N/A <br />c. N/A <br />9. Wall types <br />a. Frame, Wood, Exterior <br />b. Frame, Wood, Adjacent <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. N/A <br />c. N/A <br />II. Ducts <br />a. Sup: Unc. Ret: Unc. AH: Attic <br />b. N/A <br /> <br />Glass/Floor Area: 0.12 <br /> <br />New <br />Single family <br />I <br /> <br />Yes <br />1075 ft' <br /> <br />128.3 ft' <br />0.0 ft2 <br />0.0 ft' <br />0.0 ft' <br /> <br />R=4.0, 1075.0ft' <br /> <br />R= 11.0, 1041.0 ft' <br />R=II.O, 238.5 ft' <br /> <br />R=30.0, 1075.0 ft' <br /> <br />Sup. R=6,O, 200.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 24.0 kBtu/hr <br />SEER: 10.00, Unducted <br /> <br />3 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 24.0 kEtu/hr <br />HSPF: 7.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br /> <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0.90 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HVAC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF- Whole house fan, <br />PT-Programmable Thermostat, <br />RB-Attic radiant barrier, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />CF, <br /> <br />Total as-built points: 17374.00 <br />Total base points: 19982.00 <br /> <br />I hereby certify that the plans and specifications covered <br />by this calculation are in compliance with the Florida <br />Energy Code. <br /> <br />PREPARED BY: <br />DATE: <br /> <br />Francis J Vari <br />t-J.r~o() <br /> <br />I hereby certify that this b <br />compliance with the <br />OWNERI <br />DATE: <br /> <br /> <br />PASS <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br /> <br />EnergyGauge@ (Version: FLRCNA-200) <br />