Laserfiche WebLink
<br />Exterior Lighting Power Allowance <br /> <br />2275.00 W <br /> <br />******** PASSES ******** <br /> <br />LIGHTING SYSTEM CONTROL REQUIREMENTS: <br /> <br /> TOTAL EQUIVALENT <br /> SPACE NO. CONTROLS CONTROL POINTS <br />NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA <br />56 Worship/Co 13300.0 1 On/Off 12 On/Off :1 18 > 16 <br />56 Worship/Co 4500.0 1 On/Off 9 On/Off 13 > 6 <br /> <br />******** PASSES ******** <br /> <br />PROJECT TITLE <br />BUILDING TYPE <br />BUILDING LOCATION <br />BUILDING AREA(ft2) : <br /> <br />ALLIANCE CHURCH <br />Assembly <br />Zephyrhills <br />17800 <br /> <br />HVAC SYSTEM REQUIREMENTS: <br /> <br /> I . . <br />Cooling System Measure Minim. Minim. System System Result Result <br /> Type #1 #2 #1 #2 Eff.#l Eff.#2 for #1 for #2 <br />Evap. Cooled EER, IPLV 9.60 9.00 12.00 12.00 PASSES PASSES <br />Evap. Cooled EER, IPLV 10.50 9.70 12.00 12.00 PASSES PASSES <br />Heating System Measure Minimum Reg. Efficiency Result <br />Ele. Resis. Et 0.92 N/A <br />Ele. Resis. Et 0.92 N/A <br /> <br />******** PASSES ******** <br /> <br />AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS: <br /> <br />Zone # Duct Location <br /> <br />Minimum R-Value <br /> <br />Design R-Value <br /> <br />Result <br /> <br />1. Conditioned Space <br />2. Unconditioned Space <br /> <br />0.00 <br />4.20 <br /> <br />6.00 <br />6.00 <br /> <br />N/A <br />PASSES <br /> <br />******** PASSES ******** <br /> <br />PROJECT TITLE <br />BUILDING TYPE <br />BUILDING LOCATION <br />BUILDING AREA(ft2) : <br /> <br />ALLIANCE CHURCH <br />Assembly <br />Zephyrhills <br />17800 <br /> <br />WATER HEATING SYSTEM REQUIREMENTS <br /> <br /> I I . <br />System Measure Minimum Maximum Design Design Result <br />Type EF / Et SL EF / Et SL <br />Electric <= 12kW EF 0.8770 0.0000 0.920 0.020 PASSES <br />Electric <= 12kW EF 0.8900 0.0000 0.920 0.020 PASSES <br />