My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
00-9673
Zephyrhills
>
Building Department
>
Permits
>
2000
>
00-9673
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2006 6:33:28 AM
Creation date
9/19/2006 6:46:37 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
00-9673
Building Department - Name
ALLIANCE CHURCH
Address
6251 FT KING RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Whole Building Performance Method for Commercial Buildings <br /> <br />Form 400A-97 <br /> <br />ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br /> <br />FLA/COM-97 Version 2.2 <br /> <br />PROJECT NAME_ALLIANCE CHURCH <br />ADDRESS: _ZEPHRYHILLS <br />_FLORIDA <br />OWNER: _ALLIANCE FACILTY <br />AGENT: <br /> <br />PERMITTING OFFICE: <br />_Zephyrhills <br />CLIMATE ZONE: _4 <br />PERMIT NO: 3! ~ Gj {'7 r <br />JURISDICTION NO:_611600 <br /> <br />BUILDING TYPE: _Assembly <br />CONSTRUCTION CONDITION: New construction <br />DESIGN COMPLETION: _Finished Building <br />CONDITIONED FLOOR AREA: _17800 <br />MAX. TONNAGE OF EQUIPMENT PER SYSTEM: ____ <br /> <br />NUMBER OF ZONES: 2 <br /> <br />23 <br /> <br />COMPLIANCE CALCULATION: RESUL~ <br />METHOD A DESIGN CRITERIA <br />----------------- ------ -------- ------ <br />A. WHOLE BUILDING 69.03 100.00 PASSES <br />PRESCRIPTIVE REQUIREMENTS: <br />LIGHTING <br /> EXTERIOR LIGHTING 350.00 2275.00 PASSES <br /> LIGHTING CONTROL REQUIREMENTS PASSES <br />HVAC EQUI PMENT <br /> COOLING EQUIPMENT <br /> 1. EER 12.00 9.60 PASSES <br /> IPLV 12.00 9.00 PASSES <br /> 2. EER 12.00 10.50 PASSES <br /> IPLV 12.00 9.70 PASSES <br /> HEATING EQUIPMENT <br /> 1. Et 0.92 N/A <br /> 2. Et 0.92 N/A <br /> AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS <br /> 1. Conditioned Space 6.00 0.00 N/A <br /> 2. Unconditioned Space 6.00 4.20 PASSES <br /> REHEAT SYSTEM TYPES USED <br /> NO REHEAT SYSTEM is USED <br />WATER HEATING EQUIPMENT <br /> 1. EF 0.92 0.88 PASSES <br /> 2. EF 0.92 0.89 PASSES <br /> PIPING INSULATION REQUIREMENTS <br /> 1. Circulating 1. 00 0.78 PASSES <br /> 2 . Non-Circulating 1. 00 0.78 PASSES <br /> <br />---------------------------------------------------------------------------- <br /> <br />COMPLIANCE CERTIFICATION: <br /> <br /> <br />Review of the plans and specifica- <br />tions covered by this calculation <br />indicates compliance with the <br />Florida Energy Efficiency Code. <br />