<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />PERMIT #: <br /> <br />ADDRESS: Lot: 1~ Sub: SOV Ph I, Plat: PB 1 Page 55, Zephyrhills, FI, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />Maximum:.3 cfm/sq.ft. window arEla; .5 cfm/sq.ft. door area. <br />Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />, penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from, and is sealed to, tf1.efo,uJ1dation to the top plate. <br />606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />loJ..h.epi'!ril!letElr,J)enetrations and seams.____ <br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />in~allecJ that is seaIElcl~i1El.2..erirTlete..r,_atpenE!trations and seams. <br />606.1.ABC.1.2.4 I Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />,_,___ _,. u_' cOllcJ.IJioned space, tested _ ______'_ _u __ <br />,E>06,1,ABQ,1:z.,5. 1 Air_bilrrier on perimeter of floor cavity betwElElrlfloo@..__________ _______ <br />606..1.. ..ABC.. .1.3 I Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />_ have combustion air. <br />- - -------- ......-.. --.--.. - - - <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirerT1-~ntsi;-T~bl~-6~12, S";;itct;'or c1earlyn~arked circ~it----I-- <br />n________ I breaker (electric) or cutoff (ga~) mu~Ll:JejJrovided. Externa!.Qrl:J_uilt-inheat traQre_qlJi!.~ ! <br />Swimming Pools & Spas 612.1 i Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />. .--J efficiency of 78%. ,_____ ______n_'__ <br />! Water flow must be restricted to no more than 2.5 Q.Cl11cJll..s..2er minute at 80 PSIG. <br />! All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />s..e~a.!El.r.e_a.clily_a~<:.~sible_mall..u<l1 o!autornatic thermostat fore<lc.hs~tem <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides <br />Common ceiling & floors R-11. <br /> <br />COMPONENTS <br /> <br />Exterior Windows & Doors <br />Exterior & Adjacent Walls <br /> <br />SECTION <br />606,1.ABC.1.1 <br />1----- <br />I 606.1.ABC.1.2.1 <br /> <br />Floors <br /> <br />Ceilings <br /> <br />I <br />I <br /> <br />----t-----. -- <br />, 606.1.ABC.1.2.3 <br /> <br />Recessed Lighting Fixtures <br /> <br />Multi-sto Houses <br />Additional Infiltration reqts <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />HVAC Controls <br />Insulation <br /> <br />607.1 <br />,6041,602.1 <br />I <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-97 <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />CHECK <br /> <br />EnergyGauge@/FlaRES'97 FLRCNA-200 <br />