Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:, , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/SlI.ft. window area' .5 cfm/sa.ft. door area. <br />Exterior & Adjacent Walls 606_1.ABC,1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the too nlate. <br />Floors 606_1.ABC.1 .2.2 Penetrations/openings> 1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetrations and seams, <br />Ceilings 606.1.ABC_1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access_ EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the Derimeter at nAnetrations and seams_ <br />Recessed Lighting Fixtures 606.1,ABC_1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned soace tested. <br />Multi-storv Houses 606.1.ABC.1_2.5 Air barrier on nerimeter of floor cavitv between floors. <br />Additional Infiltration reqts 606.1.ABC_1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bvall residencesJ <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (electric\ or cutoff (aas\ must be Drovided. External or built-in heat traD reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiencv of 78%. <br />Shower heads 612_1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG_ <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 SeDarate readilv accessible manual or automatic thermostat for each system_ <br />Insulation 604.1, 602_1 Ceilings-Min, R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-97 <br /> <br />EnergyGauge@/FlaRES'97 FLRCNA-200 <br />