Laserfiche WebLink
<br />FORM.600A-97 <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br /> <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br /> <br />BURNETT 1022 SFL Builder: BURNETT HOMES <br />Permitting Office: <br />Permit Number: <br />Jurisdiction Number: <br /> <br />Project Name: <br />Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />Central <br /> <br />I, New construction or existing <br />2. Single family or multi-family <br />3. Number of units, if multi-family <br />4_ Number of Bedrooms <br />5, Is this a worst case? <br />6_ Conditioned floor area (ft2) <br />7. Glass area & type <br />a_ Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SC/SHGC - single pane <br />d, Tint/other SC/SHGC - double pane <br />8, Floor types <br />a, Slab-On-Grade Edge Insulation <br />b. N/A <br />c. N/A <br />9, Wall types <br />a. Frame, Wood, Exterior <br />b, N/A <br />c. N/A <br />d, N/A <br />e, N/A <br />10. Ceiling types <br />a. Under Attic <br />b. Under Attic <br />c. N/A <br />I I, Ducts <br />a_ Sup: Unc. Ret: Unc. AH: Attic <br />b. N/A <br /> <br />New <br />Single family <br />1 <br />2 <br />No <br />1 022 ft2 <br /> <br />171.0ft2 <br />0_0 ft2 <br />0_0 ft2 <br />0.0 fr2 <br /> <br />R=O,O, 145,O(p) fr <br /> <br />R=II.O, 1073.0 ft2 <br /> <br />R=30.0, 1022.0 fr2 <br />R=19,O, 36,0 fr2 <br /> <br />Sup. R=6.0, 90.0 ft <br /> <br />12, Cooling systems <br />a. Central Unit <br /> <br />Cap: 22.6 kBtu/hr <br />SEER: 10.00 <br /> <br />b, N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 22_8 kBtu/hr <br />HSPF: 720 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br /> <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0,88 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />RB-Attic radiant barrier, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />Glass/Floor Area: 0.17 <br /> <br />Total as-built points: 14371.00 <br />Tot I base points: 15731.00 <br /> <br />PASS <br /> <br /> <br />I hereby certify that the pia <br />by this calculation are in <br />Energy Code. <br /> <br />PREPARED BY: <br />DATE: t1--'Z{-cc> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br /> <br />BUILDING OFFICIAL: <br />DATE: <br /> <br />EnergyGauge@ (Version: FLRCNA-200) <br />