My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
00-9819
Zephyrhills
>
Building Department
>
Permits
>
2000
>
00-9819
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2006 8:31:22 AM
Creation date
9/20/2006 2:30:51 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
00-9819
Building Department - Name
CEVALLOS,JUAN
Address
ABBOTT STATION
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. .~eoWer~BonarM.. .... . .... ...: .:.. . .. '.. .. <br /> <br />~ / . . '. . <br /> <br />54.0 Power-Bond <br /> <br />54.1 Introduction <br /> <br />The Power-Bond Epoxy Pump System consists of a self <br />contained pump style cartridge in which the adhesive <br />components are mixed. A standard manually operated <br />caulking tool can be used in the installation of thread- <br />ed rod in solid concrete and masonry materials. <br />Power-Bond epoxy bonds the anchor rod to the base <br />material so no expansion forces are exerted against <br />the walls of the hole in the base material. This makes <br />the mortar ideal for use in anchoring to a variety of <br />base materials ranging from soft common brick to <br />hard marble or granite. <br /> <br />54.2 Product Description <br /> <br />The Power-Bond Epoxy Pump System is supplied in 10 <br />fluid ounce cartridges to meet the needs of most <br />smaller applications. For easy pumping, a lower viscos- <br />ity epoxy material is used as opposed to the paste style <br />epoxies used in side by side cartridge systems. Once <br />the material in the cartridge is mixed, it must be used <br />within the specified gel time. The cartridge is <br />designed for use in a standard heavy duty caulking <br />gun. <br /> <br />~.."...".......'... <br />- "..... <br /> <br /> <br />~ .... <br />.. ..... <br />. . . . <br />- .... <br />.,:.;.;.:." <br />..:::~:., <br /> <br /> <br />Each pump cartridge contains pre-measured amounts <br />of epoxy resin and hardener which are separated by a <br />set of special engineered plastic barrier rings. As the <br />pump is actuated. the barrier rings are pulled to the <br />top of the cartridge allowing the components to flow <br />together. As the cartridge is pumped, the compo- <br />nents are mixed together neatly and safely. Once the <br />epoxy has been thoroughly mixed, the plunger handle <br />is pulled up to extend the built-in mixing nozzle. The <br />handle portion of the nozzle is then removed and the <br />cartridge is ready for use. Since the epoxy must be <br />used within the specified gel time once the cartridge is <br />actuated, the best installation method is to prepare <br />the anchor holes in advance and have the anchor rods <br />ready prior to mixing the components. <br />Power-Bond epoxy can be used anchor threaded rod, <br />bolts, and reinforcing bars into concrete and other <br />solid base materials. It is not recommended for use <br />with screen tubes due to its low viscosity. <br /> <br />54.3 Mixing Guidelines <br /> <br />Pull plunger handle in the direction <br />shown until the white barrier rings <br />reach the top of the cartridge. Pull <br />hard to insure divider has been <br />opened and pulled to the top of the <br />cartridge. <br /> <br />While holding the bottom of the car- <br />tridge, mix the epoxy by pumping the <br />plunger handle. Be sure to use full <br />strokes to insure the material is fully <br />mixed. Do not use material that is not <br />mixed properly. <br /> <br />Upon completion of mixing, pull the <br />plunger handle in the direction shown <br />to extend the built-in nozzle. Be sure <br />the plunger is completely extended. <br />Unscrew the handle portion of the <br />plunger. The nozzle has an 0.0. of <br />0.420 inches. <br /> <br />Insert into a caulking gun and dis- <br />pense material. For use in anchoring, <br />follow proper hole preparation proce- <br />dures. Material must be allowed to <br />cure for the specified time prior to <br />loading. <br /> <br /> <br />... ; I <br />. '-.~ <br /> <br /> <br />t <br />! <br /> <br />'.", i'_,_' <br /> <br />~ <br />..... <br /> <br />i <br /> <br />~> <br />-'~ <br /> <br />\, <br />'~ <br />..,., <br /> <br />For ease of dispensing, condition to 70 F minimum. Do not use <br />in base materials below 40 F. <br /> <br />54, 3 Power~Bond Material Properties <br /> <br />The Power-Bond adhesive is a low viscosity amine <br />based epoxy for use in a pump style cartridge. The <br />performance criteria for use as an anchoring system <br />for threaded rods and reinforcing bars are described <br />in the sections that follow. <br /> <br />Shelf Life 1 year in original cartridge <br />Storage Conditions Store dry at 40. to 90. F. <br />Color Gray <br />Useable Volume: 10 fluid ounces <br /> 18 cubic inches <br />Cartridge Weight: 1 pound <br /> <br />176 <br />
The URL can be used to link to this page
Your browser does not support the video tag.