My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
00-9823
Zephyrhills
>
Building Department
>
Permits
>
2000
>
00-9823
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2006 8:33:20 AM
Creation date
9/20/2006 2:34:01 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
00-9823
Building Department - Name
COLE,JOHN
Address
17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />680-6. Receptacles, Lighting Fixtures, Lighting Outlets, Switching Devices, and <br />Ceiling-Suspended (Paddle) Fans <br /> <br />(a) Receptacles. <br /> <br />1. A receptacle(s) that provides power for a water-pump motor(s) for, or other loads directly <br />related to the circulation and sanitation system, a permanently installed pool or fountain, as <br />permitted in Section 680-7, shall be permitted between 5 ft and 10 ft (1.52 m and 3.05 m) from <br />the inside walls of the pool or fountain, and, where so located, shall be single and of the locking <br />and grounding types and shall be protected by a ground-fault circuit interrupter(s). <br />Other receptacles on the property shall be located at least 10 ft (3.05 m) from the inside walls of <br />a pool or fountain. <br /> <br />2. Where a permanently installed pool is installed at a dwelling unit(s), at least one 125-volt 15- <br />or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of 10 ft <br />(3.05 m) from and not more than 20 ft (6.08 m) from the inside wall of the pool. This receptacle <br />shall be located not more than 6 ft 6 in. (1.98 m) above the floor, platform, or grade level serving <br />the pool. <br /> <br />3. All 125-volt receptacles located within 20 ft (6.08 m) of the inside walls of a pool or fountain <br />shall be protected by a ground-fault circuit interrupter. <br />FPN: In determining the above dimensions, the distance to be measured is the shortest path the <br />supply cord of an appliance connected to the receptacle would follow without piercing a floor, <br />wall, ceiling, doolWay with hinged or sliding door, window opening, or other effective permanent <br />barrier. <br /> <br />(b) Lighting Fixtures, Lighting Outlets, and Ceiling-Suspended (Paddle) Fans. <br /> <br />1. In outdoor pool areas, lighting fixtures, lighting outlets, and ceiling-suspended (paddle) fans <br />shall not be installed over the pool or over the area extending 5 ft (1.52 m) horizontally from the <br />inside walls of a pool unless no part of the lighting fixture or ceiling-suspended (paddle) fan is <br />less than 12 ft (3.66 m) above the maximum water level. <br /> <br />2. Existing lighting fixtures and lighting outlets located less than 5 ft (1.52 m) measured <br />horizontally from the inside walls of a pool shall be at least 5 ft (1.52 m) above the surface of the <br />maximum water level, shall be rigidly attached to the existing structure, and shall be protected by <br />a ground-fault circuit interrupter. <br /> <br />3. In indoor pool areas, the limitations of Section 680-6(b)(1) shall not apply if all of the following <br />conditions are complied with <br /> <br />a. Fixtures are of a totally enclosed type, <br /> <br />b. A ground-fault circuit interrupter is installed in the branch circuit supplying the fixture(s) or <br />ceiling-suspended (paddle) fans, and <br /> <br />c. The distance from the bottom of the fixture or ceiling-suspended (paddle) fan to the maximum <br />water level is not less than 7 ft 6 in. (2.29 m). <br /> <br />4. Lighting fixtures and lighting outlets installed in the area extending between 5 ft (1.52 m) and <br />10 ft (3.05 m) horizontally from the inside walls of a pool shall be protected by a ground-fault <br />circuit interrupter unless installed 5 ft (1.52 m) above the maximum water level and rigidly <br />attached to the structure adjacent to or enclosing the pool. <br />
The URL can be used to link to this page
Your browser does not support the video tag.