Laserfiche WebLink
<br />. FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: Lot: _, Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS ____ SECTION_ REQUIREMENTS FOR EACH PRACTICE _____~. ~ ________ _ _ _ CHECK <br />Exterior Windows & Doors 606.1.ABC.1. 1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.___~__ ~~_~___ <br />Exterior & Adjacent Walls 606.1 .ABC.1 .2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; I <br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />, I penetrations; between wall panels & top/bottom plates; between walls and floor. <br />JI.. . ". .! EXCEPTION.: Frame walls where a. continuous infiltratio.. n barri.er is.. installed t.h. at. exte.nds <br />-- -- -- - ----- - - - __~m, and is sealed to, the foundation to the tc>Qj>late. _______ ___ _ __ ___ <br />I 606.1.ABC. 1.2.2 I Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />~ ~ I EXCEPTION: Frame floors where a continuous infiltration barrie. r is_. ins.t.alled th__at_.is se. ale. d .1._ <br />to the erimeter, enetrations and seams. ~ <br />606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />I I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />I installed that is sealed at the erimeter, at enetrations and seams. <br />Recessed Lighting Fixtures r6.1.ABC.1 .2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> <br />_ J ::::,~:. ':'::~~:::;ao'" & 3" f",m '"'""":'':': ,po ~ "led W'''-:O ""'-f,"-",- 1_ <br /> <br />Multi-sto Houses ::.-:=---1606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. ~_~___~~ _ __ ----f----~ <br />Additional Infiltration reqts I 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br /> <br />Floors <br /> <br />Ceilings <br /> <br />----C. <br /> <br />PERMIT #: <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />COMPONENTS .1 SECTION <br />Water Heaters 1612.1 <br /> <br />Swimming Pools & Spas /612.1 <br />I <br /> <br />--- -- ----- --- -- - - .=h1---- <br />Shower heads 612.1 <br />-.-.- <br />Air Distribution Systems I 610.1 <br /> <br /> <br /> <br />~~~~ti~"''''''- -- }:: 602' <br /> <br />I <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-97 <br /> <br />REQUIREMENTS _~___~_~___ __~~____ I CHECK <br />Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit I <br />I breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required:...__ ! . _ <br />I. Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> <br />I :~~~:~~u8si~e--':-~slrictedt~ rl"~ ;~;th;n.i5~~Jk;n~p;~rninut~; 80PSIG~.--=--t-= .___ <br /> <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically ! <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. I <br />Ducts in unconditioned attics: R-6 min. insulation. <br />Separate readily accessible manual or automatic thermostat for each system,~-=----=_=~_= <br />I Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. I <br />I Common ceiling & floors R-11. ' <br /> <br />EnergyGauge@/FlaRES'97 FLRCNA-200 <br />