My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0122
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0122
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:43:21 PM
Creation date
10/3/2006 9:21:13 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0122
Building Department - Name
G H D
Address
NORTHLAKE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />shall be permitted to be bonded to the grounding electrode conductor, the grounded service-entrance conductor, <br />the nonflexible grounded service raceway, or any grounded service enclosure. C__tar!l~ <br /> <br />Exception: The supplemental electrode shall be permitted to be bonded to the interior metal water piping at <br />any convenient point as covered in Section 250-50, Exception. <br /> <br />Where the supplemental electrode is a made electrode as in Section 250-52(c) or (d), that portion of the bonding <br />jumper that is the sole connection to the supplemental grounding electrode shall not be required to be larger than <br />No.6 copper wire or No.4 aluminum wire. c~41r9; <br /> <br />(b) Metal Frame of the Building or Structure. The metal frame of the building or structure, where effectively <br />grounded. <br /> <br />(c) Concrete-Encased Electrode. An electrode encased by at least 2 in. (50.8 mm) of concrete, located within <br />and near the bottom of a concrete foundation or footing that is in direct contact with the earth, consisting of at <br />least 20 ft (6.1 m) of one or more bare or zinc galvanized or other electrically conductive coated steel <br />reinforcing bars or rods of not less than ~-in. (12.7-mm) diameter, or consisting of at least 20 ft (6.1 m) of bare <br />copper conductor not smaller than No.4. Reinforcing bars shall be permitted to be bonded together by the usual <br />steel tie wires or other effective means. . Co..nnRt4lr!i1 <br /> <br />(d) Ground Ring. A ground ring encircling the building or structure, in direct contact with the earth at a depth <br />below the earth's surface of not less than 2~ ft (762 nun), consisting of at least 20 ft (6.1 m) of bare copper <br />conductor not smaller than No.2. C__tar",i <br /> <br />..410-57. Receptacles in Damp or Wet Locations <br /> <br />(a) Damp Locations. A receptacle installed outdoors in a location protected from the weather or in other damp <br />locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered <br />(attachment plug cap not inserted and receptacle covers closed), <br /> <br />An installation suitable for wet locations shall also be considered suitable for damp locations. <br /> <br />A receptacle shall be considered to be in a location protected from the weather where located under roofed open <br />porches, canopies, marquees, and the like, and will not be subjected to a beating rain or water runoff. <br /> <br />(b) Wet Locations. <br /> <br />1. A receptacle installed in a wet location where the product intended to be plugged into it is not attended <br />while in use (e.g., sprinkler system controllers, landscape lighting, holiday lights, etc.) shall have an enclosure <br />that is weatherproof with the attachment plug cap inserted or removed. Connn_tar!l i <br /> <br />2. A receptacle installed in a wet location where the product intended to be plugged into it will be attended <br />while in use (e,g., portable tools, etc.) shall have an enclosure that is weatherproof when the attachment plug cap <br />is removed. C__tar!l! <br /> <br />(c) Bathtub and Shower Space. A receptacle shall not be installed within a bathtub or shower space. <br />C__tar,.~ <br /> <br />(d) Protection for Floor Receptacles. Standpipes of floor receptacles shall allow floor-cleaning equipment to <br />be operated without damage to receptacles. <br /> <br />(e) Flush Mounting with Faceplate. The enclosure for a receptacle installed in an outlet box flush-mounted on <br />a wall surface shall be made weatherproof by means of a weatherproof faceplate assembly that provides a <br />watertight connection between the plate and the wall surface. <br /> <br />(f) Installation. A receptacle outlet installed outdoors shall be located so that water accumulation is not likely to <br />touch the outlet cover or plate. C__tar9 ~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.