<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />ADDRESS:
<br />
<br />PERMIT #:
<br />
<br />N. LAKE DRIVE, ZEPHYRHILLS, FL, 33541-
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Exterior Windows & Doors 606,1,ABC,1,1 Maximum:,3 cfm/sa,ft, window area; ,5 cfm/sa,ft, door area,
<br />Exterior & Adjacent Walls 606,1,ABC,1,2.1 Caulk, gasket, weatherstrip or Seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & top/bottom plates; between walls and floor.
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from, and is sealed to, the foundation to the too olate,
<br />Floors 606,1,ABC,1.2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the perimeter, penetrations and seams,
<br />Ceilings 606, 1 ,ABC, 1,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> installed that is sealed at the perimeter, at penetrations and seams.
<br />Recessed Lighting Fixtures 606,1,ABC.1,2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br /> conditioned space, tested,
<br />Multi-story Houses 606,1,ABC,1,2,5 Air barrier on oerimeter of floor cavity between floors,
<br />Additional Infiltration reqts 606,1,ABC,1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br /> have combustion air.
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit
<br /> breaker (electric) or cutoff (aas) must be provided, External or built-in heat trap reauired,
<br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br /> efficiency of 78%,
<br />Shower heads 612,1 Water flow must be restricted to no more than 2,5 aallons per minute at 80 PSIG,
<br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610,
<br /> Ducts in unconditioned attics: R-6 min, insulation,
<br />HVAC Controls 607,1 Separate readilv accessible manual or automatic thermostat for each system,
<br />Insulation 604,1, 602,1 Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides.
<br /> Common ceiling & floors R-11.