Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br /> <br />FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br />WILIF /Williams Builder: K. Watson tV/i../F }foll1l' <br />Lot # 7 Silver Oaks Village ~aJ/g JjIRl1?JN5i//1,..., Permitting Office: CJT4f of ;Z':- P/,NI/l11t5 ::rU!- <br />Zephyrhills, fl33541- lIv.:e:iI Permit Number: tJ/gg <br />Williams Jurisdiction Number: ~ 1/ 't'I d) <br />Central <br /> <br />Project Name: <br />Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />1. New construction or existing <br />2. Single family or multi-family <br />3, Number of units, if multi-family <br />4. Number of Bedrooms <br />5. Is this a worst case? <br />6. Conditioned floor area (ft2) <br />7. Glass area & type <br />a. Clear - single pane <br />b. Clear - double pane <br />c. Tint/other SClSHGC - single pane <br />d. Tint/other SC/SHGC - double pane <br />8, Floor types <br />a. Slab-On-Grade Edge Insulation <br />b. N/A <br />c. N/A <br />9. Wall types <br />a, Frame, Wood, Exterior <br />b. N/A <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. N/A <br />c. N/A <br />11. Ducts <br />a. Sup: Unc. Ret: Unc. AH: Attic <br />b. N/A <br /> <br />New <br />Single family <br />1 <br />2 <br />No <br />1031 ft2 <br /> <br />0.0 ft2 <br />121.3 ft2 <br />0.0 ft2 <br />0.0 ft2 <br /> <br />R=O.O, 130.2(p) ft <br /> <br />R=I1.0, 1056.0 ft' <br /> <br />R=30.0, 1031.0 ft2 <br /> <br />Sup. R=6.0, 120.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit Cap: 24.0 kBtu/hr <br />SEER: I 1.00, Unducted <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump Cap: 24,0 kBtu/hr <br />HSPF: 7.00, Unducted <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br />a. Electric Resistance Cap: 30.0 gallons <br />EF: 0.97 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV-Cross ventilation. <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />RB-Attic radiant barrier, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />Glass/Floor Area: 0.12 <br /> <br />PASS <br /> <br />Total as-built points: 11807.00 <br />Total base points: 16235.00 <br /> <br />I hereby certify that the plans and specifications covered <br />by this calculation are in compliance with the Florida <br />Energy Code. <br />PREPARED BY: ~ J,.Lf~ <br />DATE: "~/'i / "I I' <br />I hereby cert y th~ this building, as designed, is in <br />compliance with the FI~rgy Code", <br />OWNERlAGENT:/ 6 e/L-~ <br />DATE: t:1 119/0/ <br />, / <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br /> <br />EnergyGauge@ (Version: FLRCNA-200) <br />