Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />PERMIT #: <br /> <br />ADDRESS: Lot # 7 Silver Oaks Village, Zephyrhills, fI, 33541- <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC,1.1 Maxlmum:.3 cfmlsa.ft, window area' ,5 cfmlsa.ft. door area. <br />Exterior & Adjacent Walls 606.1,ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windoWs/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous Infiltration barrier is installed that extends <br /> from and Is sealed to the foundation to the tOD Dlate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetratlons and seams. <br />Ceilings 606.1,ABC,1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps In gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter at oenetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/Z' clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned Snacf!! tested. <br />Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavitY between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences. \ <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements In Table 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (aas) must be Drovided, Extemal or built-in heat traD reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thennal <br /> efficiency of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons oar minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, frttings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min, insulation. <br />HVAC Controls 607.1 Seoarate readilY accessible manual or automatic thermostat for each sYstem. <br />Insulation 604.1 , 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11, <br /> <br />EnergyGauge'I'M DCA Form 6OQA-97 <br /> <br />EnergyGaugeetFlaRESt97 FLRCNA-200 <br />