Laserfiche WebLink
<br />FROM ALL-AMERICAN HOME-INSPECTORS <br /> <br />PHONE NO. <br /> <br />813 853 2711 <br /> <br />P02 <br /> <br />/~ <br /> <br />ARKAY ENGINEERING, <br />structural <br /> <br />:ti <br />title I'tf! t>J59 <br /> <br />INc. <br /> <br />. <br />engIneers <br /> <br />May 15, 2001 <br /> <br />Ryman Construction Inc. <br />37325 State Road 54 West <br />ZephyrhillB, Florida 33541 <br /> <br />Attention: Kevin Ryman <br /> <br />Re: Lot #94 - Wedgewood <br />City of Zephyrhills Building Permit *0159 <br />Arkay Bngineering, Inc. Job * 4377 <br /> <br />Dear Kevin: <br /> <br />This letter is to confirm some field conditions at the above referenced <br />project. The construction plans call for the garage slab to be stepped <br />down from the main floor of the house, but the floor was actually <br />constructed with no step down (this change is structurally acceptable) . <br /> <br />Also, the 16'-0" garage door header beam was constructed by splicing <br />12'-0" long memberG with 4'-0" long members. The splices were etaggered <br />in the two ply member. Since this header is located in a gable end <br />wall, it does not support any significant roof loads and is <br />structurally acceptable, ao conotructed. <br /> <br />If you require any further assistance with these items, please give me <br />a call at the office. <br /> <br /> <br />Inc. <br /> <br />P.E. <br /> <br /># 37296 <br /> <br />fax copy sent to Zephyrhills Building Department. 813-788-3293 <br /> <br />5600 U.S. Hwy 98 North - Suite 2 - Lakeland, Florida 33809 <br />Phone: 941-853-2711 Fax: 941-816-2116 <br />