Laserfiche WebLink
<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: , , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606,1,ABC.1,1 Maximum:,3 cfm/sQ.ft, window area; .5 cfm/sQ,ft, door area, <br />Exterior & Adjacent Walls 606,1.ABC.1 ,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the top plate. <br />Floors 606.1.ABC.1,2,2 Penetrations/openings >1/8" sealed unless backed by truss or joint members, <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter penetrations and seams. <br />Ceilings 606,1 ,ABC,1 ,2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter at penetrations and seams. <br />Recessed Lighting Fixtures 606,1 ,ABC,1 ,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned soace tested. <br />Multi-storv Houses 606,1 ,ABC ,1 ,2.5 Air barrier on oerimeter of floor cavity between floors, <br />Additional Infiltration reqts 606,1,ABC,1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612,1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (oas) must be provided, External or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiencv of 78%, <br />Shower heads 612,1 Water flow must be restricted to no more than 2.5 oallons per minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br /> Ducts in unconditioned attics: R-6 min, insulation. <br />HV AC Controls 607.1 Seoarate readily accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1,602,1 Ceilings-Min. R-19, Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-97 <br /> <br />EnergyGauge<ID/FlaRES'97 FLRCNA-200 <br />