My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0209
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0209
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:43:02 PM
Creation date
10/3/2006 10:14:39 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0209
Building Department - Name
G H D
Address
EUCALYPTUS AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />(b) Occupancy. Each occupant shall have ready access to all overcurrent devices protecting the conductors <br />supplying that occupancy. Where electric service and electrical maintenance are provided by the building <br />management and where these are under continuous building management supervision, the service overcurrent <br />devices and feeder overcurrent devices supplying more than one occupancy shall be permitted to be accessible <br />to only authorized management personnel in the following: <br /> <br />1. In multiple occupancy buildings <br /> <br />2. For guest rooms of hotels and motels that are intended for transient occupancy <br /> <br />(c) Not Exposed to Physical Damage. Overcurrent devices shall be located where they will not be exposed to <br />physical damage. <br /> <br />FPN: See Section 110-11, Deteriorating Agents. <br /> <br />(d) Not in Vicinity of Easily Ignitible Material. Overcurrent devices shall not be located in the vicinity of <br />easily ignitible material, such as in clothes closets. C......._ta" J <br /> <br />(e) Not Located in Bathrooms. In dwelling units and guest rooms of hotels and motels, overcurrent devices, <br />other than supplementary overcurrent protection, shall not be located in bathrooms as defined in Article 100. <br /> <br />. 250-50. Grounding Electrode System <br /> <br />If available on the premises at each building or structure served, each item (a) through (d), and any made <br />electrodes in accordance with Sections 250-52(c) and (d), shall be bonded together to form the grounding <br />electrode system, The bondingjumper(s) shall be installed in accordance with Sections 250-64(a), (b), and (e), <br />shall be sized in accordance with Section 250-66, and shall be connected in the manner specified in Section <br />250-70. <br /> <br />An unspliced grounding electrode conductor shall be permitted to be run to any convenient grounding electrode <br />available in the grounding electrode system or to one or more grounding electrode(s) individually. It shall be <br />sized for the largest grounding electrode conductor required among all the electrodes connected to it. <br />E.~_ta', J <br /> <br />The grounding electrode conductor shall be unspliced or spliced by means of irreversible compression-type <br />connectors listed for the purpose or by the exothermic welding process. <br /> <br />Interior metal water piping located more than 5 ft (1.52 m) from the point of entrance to the building shall not <br />be used as a part of the grounding electrode system or as a conductor to interconnect electrodes that are part of <br />the grounding electrode system. <br /> <br />Exception: In industrial and commercial buildings where conditions of maintenance and supervision ensure <br />that only qualified persons will service the installation and the entire length of the interior metal water pipe that <br />is being usedfor the conductor is exposed c......._ta.,' <br /> <br />FPN: See Sections 547-8 and 547-9 for special grounding and bonding requirements for agricultural buildings, <br /> <br />(a) Metal Underground Water Pipe. A metal underground water pipe in direct contact with the earth for 10 ft <br />(3.05 m) or more (including any metal well casing effectively bonded to the pipe) and electrically continuous (or <br />made electrically continuous by bonding around insulating joints or sections or insulating pipe) to the points of <br />connection of the grounding electrode conductor and the bonding conductors. C_ta., I <br /> <br />(1) Continuity. Continuity of the grounding path or the bonding connection to interior piping shall not rely on <br />water meters or filtering devices and similar equipment. <br /> <br />(2) Supplemental Electrode Required. A metal underground water pipe shall be supplemented by an <br />additional electrode of a type specified in Sections 250-50 or 250-52. Where the supplemental electrode is a <br />made electrode of the rod, pipe, or plate type, it shall comply with Section 250-56. The supplemental electrode <br />
The URL can be used to link to this page
Your browser does not support the video tag.