Laserfiche WebLink
<br />SECTION 111.- SCREW SPLINE (Continued) <br /> <br />itep J: Install water deflectors on Intermediate Horizontals. Remove the paper backing from the <br />water deflectors and install them on a clean, dry surface centered in the glazing pockets of the <br />Intermediate Horizontals. (See FIG. 10). <br /> <br />450-105 <br />WATER <br />DEFLECTORS <br /> <br />'l <br />~// <br /> <br />;(,~ / / <br />~/ /" <br />/' / <br />/ <br /> <br /> <br />~ <br /> <br />: I <br /> <br />I: <br />I: <br /> <br />FIG. 10 <br /> <br />450-105 <br />WATER DEFLECTOR <br /> <br />. <br /> <br />COLD WEATHER NOTE: <br />For temperatures below 400 the following precautions <br />should be taken. Just prior to installing the water deflec- <br />tor, wipe glazing pocket with a solvent or cleaning solu- <br />tion recommended by the sealant manufacturer. <br /> <br />.CAUTION: Carefully follow the recommendations con- <br />tained in the material safety data sheet provided by the <br />solvenVcleaning solution manufacturer regarding health <br />and fire/explosion risks. <br /> <br /> <br />EDGE OF GLASS <br /> <br />FIG. 11 <br /> <br /> <br />, <br /> <br />t <br /> <br />itep K: After the water deflector is installed, seal the joint between the back leg of the Horizontal and <br />the Vertical. Make sure to fill the glazing Gasket reglets in that area to prevent water from running down <br />to the lite below. (See FIG. 11). <br /> <br />12 <br />