My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0279
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0279
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:42:45 PM
Creation date
10/3/2006 11:01:49 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0279
Building Department - Name
DAVIS CONT
Address
TIMBER WY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. '-'I ,.". \...IV'\."-'-"'" <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: , Zephyrhills, FL, <br /> <br />PERMIT #: <br /> <br />6A-21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior WindONS & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sa.tt window area' .5 cfmIsa.tt door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherStrip or seal between: windONSldoors & frames, surrounding wall; <br /> foundation & wall sole or sfll plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & toplbcttom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the toe oIate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter, oenetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Belween walls & ceilings; penetrations d ceiling plane d top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frane ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the at 'ons and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearanCe & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned s~. tested. <br />Multi-Storv Houses 606.1.ABC.1.2.5 PJr barrier on oerimeter d floor cavitv between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoorS, dampers; combustion space heaters comp/y with NFPA, <br /> h8lle combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br /> <br />HVAc Controls <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br />REQUIREMENTS <br />Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />breaker electric or cutoff must be 'ded. External or built-in heat tr uired. <br />Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must h8lle a minimum thermal <br />efficien d 78%. <br />Water flON must be restricled to no more than 2.5 Ions minute at 80 PSIG. <br />All ducts, fittings, rnec:I'l.vcat equipment and plenum chambers shall be mechanically <br />attached, sealed, insulal!Eld, and installed in accordance with the criteria d Section 610. <br />Ducts in unconditioned atticS: R-6 min. insulation. <br />ate read' accessible manual or automatic thermoStat for each s tern. <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11. <br /> <br />CHECK <br /> <br />COMPONENTS <br />Water Heaters <br /> <br />SECTION <br />612.1 <br /> <br />Swimming Pools & Spas <br /> <br />612.1 <br /> <br />ShoNeI' heads <br />PJr Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />EnergyGaugeTM DCA Form 600A-97 <br /> <br />EnergyGaugecIll/FlaRES'97 FLRCNA-200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.