<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />ADDRESS: LottlS & 6 Eucalyptus-oriftwood Phase IV-B, Zephyrhllla, FL, <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS <br />Exterior WindONS & Doors <br />Exterior & Adjacent Walls <br /> <br />SECTION <br />606.1.ABC.1.1 <br />606.1.ABC.1.2.1 <br /> <br />Floors <br /> <br />606.1.ABC.1.2.2 <br /> <br />Ceilings <br /> <br />606.1.ABC.1.2.3 <br /> <br />Recessed Lighting Fixtures <br /> <br />606.1.ABC.1.2.4 <br /> <br />Multi-st Houses <br />Additional Infiltration reqts <br /> <br />606.1.ABC.1.2.5 <br />606.1.ABC.1.3 <br /> <br />PERMIT #: <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br />Maximum:.3 cfmI: .ft. windc7N area' .5 cfml .ft. door area. <br />Caulk, gasket, weatherstrip or seal between: windONS/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at comers; utHity <br />penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from and is sealed to the foundation to the t <br />Penetrations/openings >1/S" sealed unless backed by truss or joint members. <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the er and seans. <br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />installed that is sealed at the 'meter at rations and seams. <br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />conditioned s tested. <br />Air barrier on er of floor . between floors. <br />Exhaust fans \I8l1ted to outdoors, dampers; combustion space heaters comply with NFPA, <br />h8lle combustion air. <br /> <br />COMPONENTS <br />Water Heaters <br /> <br />SECTION <br />612.1 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br /> <br />Swimming Pools & Spas <br /> <br />612.1 <br /> <br />ShONer heads <br />Air Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />HV AC Controls <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br />EnergyGauge 1M DCA Form 600A-97 <br /> <br />REQUIREMENTS <br />Comply with efficiency requirements in Table 6-12. Switch or clear1y marked circuit <br />breaker electric or cutoff as must be rovided. External or built-in heat uired. <br />Spas & heated pools must have CCNerS (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />effle' of 78%. <br />WeAer flow must be restricted to no more than 2.5 Ions minute at 80 PSIG. <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />ate readi accessible manual or automatic thermosteA for each s <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11. <br /> <br />EnergyGaugelB>lFlaRES'97 FLRCNA-200 <br /> <br />CHECK <br /> <br />CHECK <br />