Laserfiche WebLink
<br />ARCO BUILDING SYS. <br />3300 HOLCOMBE BRIDGE RD. <br />NORCROSS, GA. 30092 <br /> <br />MARTIN DUKES <br />Re: JOB NO. 8706 <br />BUILDING SIZE: <br />WIDTH 40 ft. <br />LENGTH 60 ft. <br />EAVE HT 16 ft. <br /> <br />DATE: 12/21/ 0 <br /> <br />JOBSITE <br /> <br />ZEPHYRHILLS, FL <br /> <br />To whom it may concern: <br /> <br />This is to certify that the above referenced building is <br />designed in accordance with the Ninth Edition of the American <br />Institute of Steel Construction (AISC) "Manual of Steel <br />Construction" and the 1986 Edition of American Iron and Steel <br />Institute (AISI) II Cold Formed Steel Design Manual. " The <br />basic loads of the subject building meet or exceed the minimum <br />county climatic data as published in the 1996 edition of the <br />MBMA "Low Rise Building Systems Manual ". <br /> <br />Governing Code for application of design loads is as follows <br />: SBC 97 <br /> <br />Dead Load:.....................weight of metal building <br />structure only as furnished <br />by : ARCO BUILDING SYS. <br /> <br />Live Load based on the tributary area : <br /> <br />o - 200 sq. ft.........20 psf <br />201 - 600 sq. ft.......16 psf <br />over 600 sq. ft........12 psf <br /> <br />Roof Snow Load : <br />Collateral Load: <br />Wind Load <br />Seismic Coef. <br /> <br />o psf <br />o psf <br />100 mph <br />0.040 <br /> <br />This Letter of Certification applies solely to the building and its <br />component parts as furnished by : ARCO BUILDING SYS. <br />and specifically excludes any foundation, masonry, or general contract <br />work. <br /> <br />Sincerely, <br /> <br />~.f{~ ~-U. ~rC;~e;_._ <br /> <br />CHARLES W. EMBDEN, P.E. <br /> <br />/Z,///-"":- /'h ' <br />"/' c CI' Ci ,j <br />