<br />F.ORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:" , <br />6A.21INFIL TRATtON REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 6OO.1.ABC.1.1 Maximum:.3 cfmlea.ft. window area: .5 cfmlsa.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1,2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sale or sill plate; joints between exterior wall paneI$ at comers; utility <br /> penetrations; between waH panels & toplbottom plates; between walls and ftoor. <br /> EXCEPTION: Frame walls where a continuous inflltratlon barrier Is Inlitalled that extends <br /> from. and Is sealed to the foundation to the 6- ._L <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unlelSS backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous Infiltration barrier is Installed that Is eeaIed <br /> to the certmeter oenetrations and seams. <br />Ceilings 606.1,ABC.1.2,3 Between walls & ceilings; penetrations of Ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabln$ sealed to continuous air barrier; gaps In gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous lnfiItratIon barrier Is <br /> Installed that is sealed at the cerimeter at s and seams. <br />Recessed lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or rIOl'\oolC rated, installed Inside a <br /> sealed box with 1 rr clearance & 3" from Insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned SDaCe. tested. <br />Multl-storv Houses 6OO.1.ABC.1 .2.5 Air barrier on oerimeter of floor cavItv between fIoon;, <br />Addltlonallnfiltratlon reqts 6OEl.1.ABC.1.3 Exhaust fans vented to outdoors, dampef'$; combustlon space heaters comply with NFPA, <br /> have combustion air. <br /> <br /> <br />SECTION <br />612.1 <br /> <br /> <br />REQUIREMENTS <br />Comply with efflclency requirements in Table 6-12. Switch or clearly marked ciroult <br />breaker electric or cutoff as must be . External or built-in heat tra ulred. <br />Spas & heated pools must have covers (except solar heated). Non-commerc/al ~ <br />must have a pump timer. Gas spa & pool heaten5 must have a minimum thermal <br />e of 76%, <br />Water flow must be restricted to no more than .5 allons r minute at 60 PSIG, <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, ~Ied, Insulated, and installed in accordanC(! with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />S rate read' accessible manual or automatic the for each s <br />Cellings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common C(!i1ing & floors R-11. <br /> <br />CHf! K <br /> <br />Swimming Pools & Spas <br /> <br />612.1 <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />HVAC Controls <br />Insulation <br /> <br />607.1 <br />604.1 , 602.1 <br /> <br />EnergyGauge'N DCA Form SOOA-S1 <br /> <br />EnergyGaugdIFr.RES'91 FLRCNA-200 <br />