Laserfiche WebLink
<br />401.------GLAZING--ZONE <br />Elevation Type <br /> <br />BUILDING ENVELOPE SYSTEMS COMPLIANCE <br />CHECK <br /> <br />1________________________________________________v_ <br /> <br />U SC VLT Shading Area (Sqft) <br /> <br />-------------- ---------- <br /> <br />--------- --------------- <br /> <br />Adjacent <br /> <br />Commercial <br /> <br />1.31 .67 .75 None 81 <br />Total Glass Area in Zone 1 = 81 <br />Total Glass Area = 81 <br /> <br />1------------------------------------------------ <br /> <br />U Insul R Gross (Sqft) <br /> <br />402.------WALLS--ZONE <br />Elevation Type <br /> <br />--------- -------------------------------- ----- ------- ----------- <br /> <br />West <br />South <br />Adjacent <br /> <br />.084 11 400 <br />.084 11 400 <br />.084 11 1080 <br />Wall Area in Zone 1 = 1880 <br />Total Gross Wall Area = 1880 <br /> <br />1------------------------------------------------ <br /> <br />U Area (Sqft) <br /> <br />Mtl Bldg wall/R-11 <br />Mtl Bldg wall/R-11 <br />Mtl Bldg wall/R-11 <br /> <br />Batt <br />Batt <br />Batt <br />Total <br /> <br />403.------DOORS--ZONE <br />Elevation Type <br /> <br />--------- ------------------------------------------ ----- ---------- <br /> <br />South <br /> <br />.5 <br /> <br />.47 21 <br />Total Door Area in Zone 1 = 21 <br />Total Door Area = 21 <br /> <br />1------------------------------------------------ <br /> <br />Color U Insul R Area (Sqft) <br /> <br />GLASS DOOR <br /> <br />404.------ROOFS--ZONE <br />Type <br /> <br />------------------------------------ ------ ----- ------- ---------- <br /> <br />405.------FLOORS-ZONE <br />Type <br /> <br />o <br />Total Roof Area in Zone 1 = 0 <br />Total Roof Area = 0 <br /> <br />1------------------------------------------------ <br /> <br />Insul R Area (Sqft) <br /> <br />------------------------------------------------ <br /> <br />Slab on Grade/Uninsulated 3 1120 <br />Total Floor Area in Zone 1 = 1120 <br />Total Floor Area = 1120 <br /> <br />406.------INFILTRATION-------------------------------------------------- <br /> <br />I CHECK <br />Infiltration Criteria in 406.1.ABCD have been met. vi <br /> <br />MECHANICAL SYSTEMS <br /> <br />CHECK <br /> <br />------------------------------------------------------------------1----- <br /> <br />HVAC load sizing has been performed. (407.1.ABCD) v/ <br />407.------COOLING SYSTEMS----------------------------------------------- <br />Type No Efficiency IPLV Tons <br /> <br />---------------------------- <br /> <br />---------- ----- -------------- <br /> <br />4~8.~~~~~=~~;~i~ ~~~~~~S-----------=--------=~~:---=~~:------------:~~~ -~ <br /> <br />Type No Efficiency BTU/hr <br /> <br />I <br />J/__ <br /> <br />j <br /> <br />j <br /> <br />j <br /> <br />.I <br /> <br />1. Electric Resistance 1 -------~9; ---------;;~~~ .vI <br /> <br />409.------VENTILATION--------------------------------------------------- <br /> <br />ICHECJ <br />Ventilation Criteria in 409.1.ABCD have been met. V <br />410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- <br />CHECK <br /> <br />- -~=~~~~~: ~~~:~,~~;~~~~~.~~ ~;;;~.~~~~_~--,=,l,w,:i:~~i-- - - - -1- - - - - - <br /> <br />-------------------------------- <br />