<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: Oak Run, , , <br />6A-21INFIL TRATION REDUCnON COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmh!Ja.ft. windQw area' .5 cfmIsa.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.21 Caulk. gasket, weatherstrip or seal between: windowS/doors & frames, surrounding wan; <br /> foundation & wall sole or sill plate; joints between exterior wan panels at corners; utlIity <br /> penetrations; belween wan paneI$ & topIbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where 8 continuous infiltration barrier is Installed that extends <br /> from and is sealed to the foundation to the too Dlate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1 ~ seated unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the and seams. <br />Ceilings 606.1.ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic acc:ess. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> Installed that is sealed at the Mrimeter at and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installecllnside a <br /> sealed box with 1 fZ' cIearanc:e & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />I----- condltionecIllDaCf!. tested. <br />Multi-storv HoU88$ 606.1.ABC.1.25 Air barrier on llI!rimeter of floor cavitY between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combu$tion air. <br /> <br />rr <br /> <br />" <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded b all residences. <br />COMPONENTS SECTION REQUIREMENTS <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />breaker or cutoff must be . ExtemaI or built-in heat <br />Spas & heated pools must have covers (except solar heated). Non-commerclal pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />0178%. <br />Water flow must be restricted to no more than 2.5 minute at 80 PSIG, <br />All ducts, fittings, mechanical equipment and plenum chambers shaD be mechanically <br />attached, sealed, insUlated, and installed in accordance with the criteria of Section 610. <br />Ducts In u ditionecl attics: R-6 min. insulation. <br />e read! accessible manual or automatic thermostat for each s em. <br />Ceifmgs-Mln. R-19. Common wafls..Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11. <br /> <br />CHECK <br /> <br />Swimming Pools & Spas <br /> <br />612.1 <br /> <br />Shower heads <br />Air Distribution Systems <br /> <br />612.1 <br />610.1 <br /> <br />HVAC Controls <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br /> <br />EnergyGauge1M DCA Form 600A-97 <br /> <br />E~ES'97 FLRCNA-200 <br />