My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0615
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0615
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:41:27 PM
Creation date
10/26/2006 10:35:16 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0615
Building Department - Name
BOLENDER,JOHN
Address
39242 SOUTH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Chapter 2 - Components <br />Page 2-6 . <br /> <br />4. Fusible Links. <br /> <br />The fusiole link is designed to separate at a specific temper- <br />ature. releasing tension from the fusible link line, causing <br />system actuation. See Figure 2.12. <br /> <br /> <br /> <br />Figure 2-12. ML Style Fusible LInk. <br />OC2&51PC <br /> <br />Aher determining the maximum ambient temperature :oat the <br />fusible link location. select the correct fusible link according <br />to the temperature condition chart below: <br /> <br />Fusible Link <br />M:Jdel No. <br /> <br />Fl-165 <br />FL.212 <br />FL.280 <br />Fl.360 <br />Fl,450 <br />FL-SQO <br /> <br />Maximum Ambient <br />Temperature <br /> <br />950 F. (350 C.) <br />1420 F. (61' C.) <br />2100 F. (99' C.) <br />290' F. (143" C.) <br />3800 F. (1930 C.) <br />430' F. (221' C.) <br /> <br />5. Thermal Detectors. <br /> <br />Rate compensated temperature thermal detectors are nor- <br />mally open, mechanical contact closure switches designed <br />to operate at a factory preset temperature. They are avaiJ. <br />able in six preset temperatures which meet NFPA standards <br />and are UL Listed and FM Approved. After determining the . <br />maximum ambient temperature at the thermal detector loca- <br />lion, selecl the correct thermal detector according to the <br />tem;JeralUre condition ohart below: <br /> <br />Thermal <br />Detector <br />Model No. <br /> <br />TO.140 <br />TD-190 <br />TO-225 <br />TD-325 <br />TD-450 <br />TO-SOO <br /> <br />Maximum Ambient <br />Temperature <br /> <br />70' F. (21" C.) <br />120' F. (490 C.) <br />1550 F. (68' C.) <br />255" F. (124' C,) <br />380" F. (193" C,) <br />530' F. (2770 C.) <br /> <br />'. <br /> <br />;+ <br /> <br />ULEX 3437 CeX732 <br />September 29, 1998 <br /> <br />MODEL RPS-M -REMOTE <br />MECHANICAL PULL STATION <br /> <br />Remote manual control for system releasing devices is pro- <br />vided by the Model RPS-M remote mechanical pull station. <br />It is connected to the system releasing device by stainless <br />steel cable. This cable is enclosed in 1/2" EMT with corner <br />pulleys at each change in direction. The remote mechanical <br />pull station shall be located at the point of egress from the <br />hazard area. See Figure 2-13. <br /> <br />al <br /> <br />!1l <br /> <br />IN CASE OF <br /> <br />* <br /> <br /><D <br /> <br />elm <br /> <br /> <br />IlIDCa1l) M~ <br />ALlJMIMAl fACE PLATE <br /> <br />ftED IU8TlC <br />-....c IlOO <br /> <br />1U- <br />ON ALLCOftNEM <br /> <br />Figure 2-13. Model RPS-M Mechanical Pull Station. <br />_ozrc <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.