<br />FORM 6,OOA-97 <br /> <br />Code Compliance Checklist <br />Whole Building Performance Method A - Details <br /> <br />I ADDRESS:" , <br />6A-21 INFilTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmlsa.ft. window area' .5 cfmlsa,ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrlp or seal between: windOW$ldoors & frames, surrounding wall; <br /> foundation & wan sole or sill plate; joints between exterior wall panels at comers; utifrty <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous Infiltration barrier is installed that extends <br /> from and is sealed to the foundation to. the too DIat&. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >118" seaJed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier Is Installed that Is sealed <br /> to the oerimeter D9Mtratlons and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps In gyp board & top plate; <br /> attic access, EXCEPTION: Frame ceilings where a continuous Infiltration barrier Is <br /> Installed that Is sealed at the cerimeter at cenetratlons and seams. <br />Recessed Lighting Fixtures 606,1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, Installed Inside a <br /> sealed box with 112" clearance & 3" from Insulation; or Type IC rated with < 2,0 cfm from <br /> conditioned soace tested. <br />Muitl-storv Houses 606,1,ABC.1.2.5 Air barrier on oerlmeter of floor cavitY between floors, <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air, <br /> <br />41 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements In Table 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (aas) must be Drovlded. External or built-In heat tnm rlKlulred. <br />SWimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated), Non-commerclal pools <br />" must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficlencv of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons Der minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, Insulated, and installed in accordance with the criteria of Section 610, <br /> Ducts in unconditioned attics: R-6 min. Insulation. <br />HVAC Controls 607,1 SeDarate readilv accessible manual or automatic thermostat for each sYStem, <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeâ„¢ DCA Form 6OOA-97 <br /> <br />~ergyGaugeGDIFlaReS'97 FLRCNA-200 <br />