<br />. "'. "V' VVVr-\.-"", I <br /> <br />Code Complian.ce Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS:" , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior WindOlNS & Doors 606.1.ABC.1.1 Maximum:.3 cfmlsa.ft. window area' .5 cfmlsQ.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between; windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to, the foundation to the too elate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams, <br />Ceilings 606.1.ABC.1,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Fr8l1ll;l ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the oerimeter at eenetrations and seams. <br />Recessed Lighting Fixlu~ 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> ~sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned soace tested. <br />Multi-storv Houses 606.1.ABC.1.2.5 Air barrier on of floor cavitv between floors. <br />Additiona1lnfiltration req1s 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES tmust be met or exceeded bv all residences.) <br />COMPONENTS SECTION REOUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (electricl or cutoff lasS\ must be provided. Extemal or built-in heat trao reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have COIIefS (except solar heated). Non-commercial pools <br /> ~ must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%. <br />Sha.ver heads 612.1 Water flow must be restricted to no more than 2.5 aallons oar minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, ~I equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated. and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 Seoarate reaclilv accessible manual or automatic thermostat for each sYStem. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGaugeTW DCA Fonn 6OQA-97 <br /> <br />EnergyGaug~FIaRES'97 FLRCNA-200 <br />