<br />FORM 600A-97 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />, ADORESS:", <br />6A.21INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />ExterIor Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfrnlsa.ft. Window area' .5 cfmlsa.ft. door area. <br />Exterior & Adjacent Walls eoe.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: Windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints betWeen exterior wall panels at corners; utRity <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the too Dlate. <br />Floors 606.1.ABC.1.2.2 PenetrationS/openings >1/5' sealed unless backed by truss or joint Il'1embel'$. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is in$talled that is sealed <br /> to the Derimeter. Denetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceDingS; penetrations of ceRing plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic acce&S. EXCEPTION: Frame ceilings where a continuous Infiltration barrier is <br /> installed that is sealed at the DArimeter at lW'letrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type Ie rated With no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box With 1/Z' clearance & 3" from insulation; Or Type IC rated With < 2.0 cfm from <br /> conditioned SDaCe. tested. <br />Multl-storv Houses 606.1.ABC.1.2.5 Air barrier on Derimeter of floor cavltv between tJoors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply With NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEAS lJRES 'must be met or exceeded bv all residences.} <br />COMPONENTS sECTION REQUIREMENTS CHECK <br />Water Heeters 612.1 Comply With effICiency requirements in Table 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (oas) must be D1'ov/ded. External or built-in heat traD rlKlulred. <br />SWimming Pools & spas 612.1 Spas & heated pools must have covers (except soiar heated). Non-commerclal pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efflCiencv of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance WIth the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Controls 607.1 S-rate readilY accessible manual or autom2ltic thermostat for each sYStem. <br />Insulation 604.1 , 602.1 Cellings-Min. R.19, Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGauge no DCA Form 6OOA-97 <br /> <br />EnergyGaugd/FlaRES'97 FLRCNA-200 <br />